999精品在线视频,手机成人午夜在线视频,久久不卡国产精品无码,中日无码在线观看,成人av手机在线观看,日韩精品亚洲一区中文字幕,亚洲av无码人妻,四虎国产在线观看 ?

Easy removal of rust rings formed after metal foreign bodies in cornea

2016-12-05 08:58:56ShuZhangGuoFanCaoJinLiu
國際眼科雜志 2016年12期
關鍵詞:方法

Shu Zhang, Guo-Fan Cao, Jin Liu

1In-patient Department, Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210029, Jiangsu Province, China2Department of Ophthalmology, The Second Affiliated Hospital of Nanjing Medical University, Nanjing 210011, Jiangsu Province, China

?

·Original article·

Easy removal of rust rings formed after metal foreign bodies in cornea

Shu Zhang1, Guo-Fan Cao1, Jin Liu2

1In-patient Department, Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210029, Jiangsu Province, China2Department of Ophthalmology, The Second Affiliated Hospital of Nanjing Medical University, Nanjing 210011, Jiangsu Province, China

Received: 2016-03-29 Accepted: 2016-09-09

?AIM: To compare the effectiveness and outcome of two different methods for removing metal foreign bodies and rust rings from cornea.

?METHODS: Forty outpatients with cornea metal foreign body injuries were recruited. They were divided into two groups according to the methods used to remove the foreign body and the rust ring (group 1 using needle + forceps; group 2 using needle only). The effectiveness and outcome were compared across groups in term of the duration of the surgery, pain scores, and the recovery of epithelial damage, as well as the integrity of the removed rust rings, which was associated with the difficulty of the surgery.

?RESULTS: In group 1, rust rings were removed readily in one piece in one or two attempts, while in group 2, the rings were broken into several pieces before they were totally removed. The averaged surgery duration for patients in group 1 was 1.9min(37.3%)shorter than that in group 2 (P<0.001). The pain score of group 1 was also significantly lower than that of group 2 during and 1d after the surgery. In group 1, a full recovery of the corneal epithelium, indicated by negative fluorescent staining, was seen in 80% of cases 1d after the surgery, while in group 2, this was only 55%.

?CONCLUSION: The method in group 1 is easier to perform and results in better outcomes than the conventional method in group 2 for removing the rust rings formed by corneal metal foreign bodies.

metal corneal foreign body; rust ring; removal; epithelial healing

INTRODUCTION

Metal foreign body injuries to human corneas (usually caused by metal debris) are commonly seen in ophthalmology clinics[1-3]. Such injuries often lead to corneal erosions and the formation of rust rings around the foreign body within hours. The foreign body and rust ring must be clearly removed to ensure a full recovery of visual function. Usually, this is done with a small needle[3-6]. Although needle works well in removing foreign bodies, we have found that it is challenging to remove the rust ring smoothly and without causing additional damage with needle. This is largely due to the facts that 1) needle has a sharp tip and two cutting edges; 2) rust ring cannot be held by a needle, so the removing with needle requires repeated digging and picking, during which the ring is often broken into pieces before it can be removed completely. Repeated actions required also elongated the surgery duration.

With the development of micro-surgery equipment, a microscopic knot forceps is now available to handle fine surgical areas, such as the cornea.Inspired by it, we occasionally tried to use forceps to remove the rust ring in several difficult patients suffering from cornea metal foreign body injury, and we found that the outcome was surprisingly good. To the best of our knowledge, using forceps as the tool for this surgery has not been reported. Therefore we designed a controlled study as reported here to evaluate if forceps is a better method for cornea foreign body and rust ring removing. The criteria for this evaluation include surgery duration, pain score, and recovery of the cornea epithelium.

SUBJECTS AND METHODS

This was a prospective, comparative clinical study involving 40 outpatients (39 males, 1 female). The subjects were 18 to 56y old (average 32.2y) with no other ocular pathology or combined injuries. To check if the sample size was appropriate for the analysis, power analysis was done after all the samples were collected by using power analysis (GPower 3.1) software against the major index of the comparison between the two surgical approaches: the surgery time. Based upon the group means and SDs, the effective size of the sample is 0.739, and the minimal sample size to reach significant level of 0.05 and statistic power of 0.90 is 6 in each group. Each subject suffered from superficial corneal injury in one eye by metal debris that was not thermal. They were randomly (listed in advance by table of random numbers) assigned into the two groups, each containing 20 subjects. The time delay between injury and surgery in this sample ranged from 4 to 24h. The two groups were matched in age, the size of the corneal lesions, as well as the time delay (Table 1). Informed consent was obtained from every patient before the surgery and the experimental component of the surgery was explained to the patient.

Surgical Procedure In each patient, the anterior segment of the injured eye was examined carefully using a slit lamp before surgery. The eyes were kept open manually by the surgeon during the surgery. After obtaining topical analgesia with oxybuprocaine hydrochloride eye drops (Santen Pharmaceutical, Japan), a needle was placed tangentially to the eyeball with the bevel side facing upwards at the spot of the injury. Then, a levering action was used to remove the foreign body from the cornea. If the removal was incomplete after this action (with a remaining of a rust ring), the subject was further treated differently according to the group. In group 1, the residual material and rust ring were removed using a needle together with a forceps. The rim of the ring was elevated slightly by the needle tip so that it could be grasped easily with the forceps. Then, the entire ring was pulled away gently using the forceps (Figure 1). In group 2, the residual material and rust ring were removed using a needle alone. In this group, several trials of digging were usually required to remove the whole ring because it was often broken into pieces. All subjects were treated by one surgeon. Postoperatively, topical ointment antibiotics was applied and continued for 2-3d until the fluorescent staining test was negative, eye cover was not mandatory. All patients of both groups received the same outpatient review.

Table 1 Patient information

PatientsGroup1(forceps)Group2(needle)Eyes(M/F)20(19/1)20(20/0)Eyes(R/L)20(15/5)20(16/4)Meanage(a)±SD31.6±9.233.9±9.0Timefrominjury(h)±SD13.6±6.012.7±5.8Diameterofcornealdamagingineyes <1mm911 1-2mm108 >2mm11Surgeryduration(min)±SD3.2±0.7155.1±0.99

Figure 1 Image of an intact rust ring on a cotton swab after it was pulled out using forceps.

Outcome Evaluations A trained judge was employed to do the semi-quantitative evaluation. The information of grouping and days after the surgery were blinded from the judge to avoid bias. The integrity of the removed rust rings was compared between the two groups. If a removed rust ring was broken into two pieces or more, the integrity was considered as lost. The surgery duration in both groups was documented and analyzed. Patients were asked to rank the pain they experienced during, and 1 and 2 days after the surgery using a four-point scale (0=none; 1=little; 2=some; 3=much) (Table 2)[7-9]. The ranking of pain during the surgery was done immediately after the surgery.

The area of epithelial damage was examined with a micro-slit lamp (Haag-Streit 900, Gartenstadtstrasse, Switzerland) 24, 48, and 72h after the surgery, with blue light illumination after instilling fluorescent solution to show the lesion.

RESULTS

In 19 of 20 eyes in group 1, the rust ring was removed intact (Figure 1) in one or two actions with the forceps, while in group 2, all rings were broken into at least three pieces before they were removed completely.

The average surgery time for group 1 was 3.2±0.715min (mean±SD), as compared with 5.1±0.99min for group 2. The difference was 1.9min or 37.3%. The difference in surgery time was statistically significant [Student’st-test,t=6.958, degree of freedom (DF)=38,P<0.001].

Table 2 Pain scores as indicate by the number of eyes

EyesDuringoperative1dpostoperative2dpostoperativePainscores012301230123Group1711201550020000Group23494923018202P<0.001<0.001>0.05

Pare the results of post-hoc pairwise comparisons (Tukey) between groups.

Table 2 shows the pain scores given by the patients in both groups at the different time points. Two-way analysis of variance (ANOVA) in a general linear model showed significant group (F1=20.504,P<0.001) and time (F2=38.706,P<0.001) effects.Post-hoccomparisons (Tukey test) for the factor of group showed significantly (P<0.001) less pain in group 1 during and 1 day after the surgery. The difference was not significant 2 days after the surgery, which was likely due to the near-total recovery at this time (ceiling effect).

A full recovery of cornea was verified by the negative fluorescent staining in this study. As shown in Figure 2, such a full recovery was seen in 16 cases 1 day after the surgery in group 1, but was found only in eleven cases in group 2 at this time point. Again, between-group difference in the case of full recovery was not seen 3 days after the surgery due to the full recovery at this time.

DISCUSSION

Occupational eye injuries caused by metal debris are common in some industrial settings[1-4,6,10]. In addition to the direct mechanical damage to the cornea, metallic foreign bodies can also cause a deposit in the cornea epithelium and stroma due to the oxidative reaction of iron[11]. The reaction may result in corneal erosions and the formation of a rust ring surrounding the metal debris. This can happen within hours of the injury. If not treated promptly, the rust ring may cause corneal scarring and infection. Thus, to pursue complete removal of both the foreign body and the rust ring with minimal additional injury from the surgery is the goal of the clinical management of eye injury by metal debris[6,12].

Several tools are commonly used in this surgery, including needles, lancets, hand-held microdrills, and small chalazion curettes[5-6,13-14]. We have found that each of these tools is adequate for removing the foreign body itself, but they can cause damage to the surrounding tissue when they are used to remove the rust ring. Additional lesion is often created when repeated actions were taken to remove the residual ring when it was broken after first try.

Through preliminary use with surprisingly good result, we believed that forceps is more convenient for removing the rust ring than other tools. Therefore, a controlled comparison was conducted to confirm this advantage of forceps. In this study, we demonstrated that using forceps to remove the rust ring shortened the surgery and resulted in better outcomes. As soon as the rim of the ring being grasped by the forceps, it can be pulled out easily without further contact between the forceps and the cornea tissue and the ring can be pulled out in one piece. Unlike the surgery using needle, the cornea was barely contacted by the forceps. This is the reason of much less or no further lesion is created during the removal of the rust ring using forceps. In contrast, when using a needle, the rust ring was often broken into pieces before it was removed completely. This resulted in longer surgery time and additional damage.

Figure 2 Between group comparison of cornea recovery after the surgery. A full recovery was verified as negative fluorescent staining in the cornea. The number of eyes that were fully recovered was larger in group 1 at the first and the second day after the surgery.

After removing the rust ring, the lesion on the cornea in group 1 was limited to the area covered by the ring, while the corneal lesion in group 2 was much larger and resulted partially from the multiple attempts to remove the remaining pieces of the broken rust ring. Less corneal damage and shorter surgical duration resulted in less pain during and after the maneuver (Table 2), and quicker recovery of the corneal wounds[15-19]. The longer surgical time in group 2 reflected the greater difficulty in handling the rust ring and was associated with an additional wound, which also delayed the healing.

In summary, we demonstrated clear advantages of the needle forceps approach in removing metal foreign bodies with rust rings over the conventional needle-only approach.

1 Yokogawa H, Kobayashi A, Yamazaki N, Masaki T, Sugiyama K. Surgical therapies for corneal perforations: 10 years of cases in a tertiary referral hospital.ClinOphthalmol2014;8:2165-2170

2 Ozkurt ZG, Yuksel H, Saka G, Guclu H, Evsen S, Balsak S. Metallic corneal foreign bodies: an occupational health hazard.ArqBrasOftalmol2014;77(2):81-83

3 Gumus K, Karakucuk S, Mirza E. Corneal injury from a metallic foreign body: an occupational hazard.EyeContactLens2007;33(5):259-260

4 Welch LS, Hunting KL, Mawudeku A. Injury surveillance in construction: eye injuries.ApplOccupEnvironHyg2001;16(7):755-762

5 Health tips. Managing postnasal drip.MayoClinHealthLett2002;20(6):3

6 Beyer H, Cherkas D. Corneal foreign body removal using a bent needle tip.AmJEmergMed2012;30(3):489-490

7 Aslankurt M, Aslan L, Bakan AM, Aksoy A, Silay E, Yldz H. Pain and cooperation in patients having dominant-side or nondominant-side phacoemulsification.JCataractRefractSurg2014;40(2):199-202

8 Sauder G, Jonas JB. Topical anesthesia for penetrating trabeculectomy.GraefesArchClinExpOphthalmol2002;240(9):739-742

9 Kernt M, Cheuteu RE, Cserhati S, Seidensticker F, Liegl RG, Lang J, Haritoglou C, Kampik A, Ulbig MW, Neubauer AS. Pain and accuracy of focal laser treatment for diabetic macular edema using a retinal navigated laser (Navilas).ClinOphthalmol2012;6:289-296

10 Xu Z, Yu X, Li Z, Wang L. The role of in vivo confocal microscopy in the diagnosis of hidden corneal foreign bodies.JIntMedRes2014;42(1):145-152

11 Witherspoon SR, Hogan RN, Petroll WM, Mootha VV. Slit-lamp, confocal, and light microscopic findings of corneal siderosis.Cornea2007;26(10):1270-1272

12 Austin PE, Ljung M, Dunn KA. A new model for teaching corneal foreign body removal.AcadEmergMed1995;2(9):831-834

13 Egger SF, Huber-Spitzy V, Alzner E, Scholda C, Vecsei VP. Corneal wound healing after superficial foreign body injury: vitamin A and dexpanthenol versus a calf blood extract. A randomized double-blind study.Ophthalmologica1999;213(4):246-249

14 Clark WN. Embedded corneal foreign body in a child? Try a chalazion currette.CanJOphthalmol1999;34(7):394

15 Liu X, Zhao Y, Yang Y, Xu Y, Jiang Y, Dong F, Long Q. Mycobacterium massiliense keratitis.OptomVisSci2012;89(6):E944-E947

16 Yigit O, Yürüktümen A, Arslan S. Foreign body traumas of the eye managed in an emergency department of a single-institution.UlusTravmaAcilCerrahiDerg2012;18(1):75-79

17 Domniz Y, Lawless M, Sutton GL, Rogers CM, Meagher LJ. Successful treatment of Paecilomyces lilacinus endophthalmitis after foreign body trauma to the cornea.Cornea2001;20(1):109-111

18 Gupta S, Sehra S, Gogia V, Khokhar S, Agarwal T. Corneal nerve regeneration after foreign body removal on in vivo confocal microscopy.CanJOphthalmol2013;48(5):e125-e128

19 Wipperman JL, Dorsch JN. Evaluation and management of corneal abrasions.AmFamPhysician2013;87(2):114-120

取出角膜金屬異物和銹環的改良方法

張 舒1,曹國凡1,劉 錦2

(作者單位:1210029 中國江蘇省南京市,南京醫科大學附屬眼科醫院住院部;2210011 中國江蘇省南京市,南京醫科大學第二附屬醫院眼科)

張舒,畢業于東南大學,本科,主任醫師,副教授,研究方向:眼表疾病。

張舒.zhangs60@aliyun.com

目的:比較用兩種方法取出角膜金屬異物和銹環的效果。方法:將40例門診角膜金屬異物患者分為兩組。第1組(20例)采用注射針頭配合鑷子取出異物和銹環;第2組(20例)采用注射針頭取出異物和銹環。將兩組間操作時間長短、患者疼痛程度、角膜上皮損傷修復時間和取出銹環的完整性進行比較。結果:第1組患者的角膜銹環經過一至兩次嘗試后完整取出;而在第2組中,銹環往往破碎成數塊之后才能全部取出。第1組患者的平均手術時間較第2組短1.9min(37.3%)(P<0.001)。第1組患者術中和術后1d的疼痛評分也明顯低于第2組。第1組患者80%的眼術后1d角膜上皮細胞已修復,熒光染色呈陰性;而在第2組,同期只有55%的眼角膜熒光染色呈陰性。結論:第1組取出角膜金屬異物和銹環所采用的方法較第2組的傳統方法更容易操作且療效更好。

角膜金屬異物;銹環;取出;上皮愈合

Shu Zhang. In-patient Department, Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210029, China. zhangs60@aliyun.com

10.3980/j.issn.1672-5123.2016.12.03

:Zhang S, Cao GF, Liu J. Easy removal of rust rings formed after metal foreign bodies in cornea.GuojiYankeZazhi(IntEyeSci) 2016;16(12):2180-2183

引用:張舒,曹國凡,劉錦. 取出角膜金屬異物和銹環的改良方法.國際眼科雜志2016;16(12):2180-2183

猜你喜歡
方法
中醫特有的急救方法
中老年保健(2021年9期)2021-08-24 03:52:04
高中數學教學改革的方法
河北畫報(2021年2期)2021-05-25 02:07:46
化學反應多變幻 “虛擬”方法幫大忙
變快的方法
兒童繪本(2020年5期)2020-04-07 17:46:30
學習方法
用對方法才能瘦
Coco薇(2016年2期)2016-03-22 02:42:52
最有效的簡單方法
山東青年(2016年1期)2016-02-28 14:25:23
四大方法 教你不再“坐以待病”!
Coco薇(2015年1期)2015-08-13 02:47:34
賺錢方法
捕魚
主站蜘蛛池模板: 尤物国产在线| 亚洲国内精品自在自线官| 91在线播放免费不卡无毒| 日韩在线2020专区| 国产综合网站| 欧美无专区| 久久久久国产一级毛片高清板| 国产乱人伦精品一区二区| 激情成人综合网| 国产精品精品视频| 蜜臀AVWWW国产天堂| 国产女人水多毛片18| 看你懂的巨臀中文字幕一区二区| 久久a级片| 国产精品成人一区二区| 日韩不卡免费视频| 亚洲欧美不卡中文字幕| 国产青榴视频| 欧美成人精品在线| 丝袜无码一区二区三区| 亚洲美女一区二区三区| 中文字幕自拍偷拍| 欧美va亚洲va香蕉在线| 国产美女丝袜高潮| 中文字幕人妻无码系列第三区| 真实国产精品vr专区| 日韩av无码精品专区| 日本免费新一区视频| 亚洲一区二区成人| 激情综合婷婷丁香五月尤物| 国产精品xxx| 午夜国产精品视频| 国产精品视频a| 午夜精品久久久久久久99热下载| 免费观看亚洲人成网站| 日本手机在线视频| 青青国产视频| 国产www网站| 97视频精品全国免费观看 | 国产在线精品99一区不卡| 久久久久亚洲av成人网人人软件| 亚洲综合第一页| 在线无码九区| 99热这里都是国产精品| 九九九九热精品视频| 国产性生大片免费观看性欧美| 亚洲免费黄色网| 九九久久精品国产av片囯产区| 天天躁夜夜躁狠狠躁图片| 一本色道久久88| 日韩色图区| 欧美精品xx| 国产亚洲视频中文字幕视频| 亚洲精品视频免费观看| 老司机久久99久久精品播放| 国产激情国语对白普通话| 美女扒开下面流白浆在线试听 | 白浆视频在线观看| 丝袜高跟美脚国产1区| 97久久免费视频| 熟女视频91| www.99在线观看| 亚洲一级毛片在线观播放| 欧美人在线一区二区三区| 在线国产91| 欧美成人第一页| 操操操综合网| 黄色成年视频| 亚洲国语自产一区第二页| 国产麻豆精品手机在线观看| 欧美专区在线观看| 久久中文字幕2021精品| 四虎国产在线观看| 国产精品七七在线播放| 高清无码手机在线观看| 国产精品国产三级国产专业不| 国产成人盗摄精品| 特级欧美视频aaaaaa| 国产成人乱无码视频| 欧美精品高清| 国产无遮挡猛进猛出免费软件| 91精品国产自产91精品资源|