摘 要:隨著社會的發展,人們對居住的生活環境要求也越來越高,居住建筑的污水排放設計會直接影響環境質量,因此,排水設計在結構設計中也被重視起來了。本文以一棟位于華南地區的12層公寓(第一層設為大廳,第二至十二層為宿舍)為實例來介紹排水系統。采用生活污水和生活廢水合流制,并采用U-PVC管。
關鍵詞:排水系統設計
中圖分類號:TU82文獻標識碼:A文章編號:1674-098X(2011)08(a)-0089-02
Abstract:With the development of society, people living environment are increasingly high requirements, design of residential buildings will directly affect the effluent quality of the environment,Therefore, the drainage design in the structural design is also being taken seriously again.The engineering is to be a twelve-floor building. It’s located in city of South china.( The floor is designed to be a hall,The second to twelfth is to be boarding houses.)Water drainage system. In the sewage pipes, the domestic soil and domestic wastewater flow jointly.And we choose PVC pipes.
Key Word:Water drainage system,design.
1 工程概述
據上級有關部門批準的任務書,擬在華南某市修建一幢12層的公寓,建筑總高度為40.8米,地上十二層,總占地面積約800平方米,建筑面積約19800平方米,該樓一樓部分作為商場用面積,二層至十二層為單身職工宿舍。
2 排水工程設計原則及說明
本著合理布置室內各系統管線,又立足于外部系統,以便于施工及操作的原則,認真合理設計各系統布置方式及位置。
3 室內排水工程
3.1 排水體制
根據本建筑的建筑特點以及該公寓建筑所產生的污廢水性質及污染程度,結合室外排水體制,本建筑內衛生器具類型、數量以及布置情況,采用生活污水和生活廢水合流排放體制。
3.2 排水管網布置
本建筑排水管道采用明裝,立管分設在各個衛生間和廚房,2~12層衛生間的排水橫干管布置在一層天花板下的吊頂內,排出管橫管在一樓衛生間下排出。2~12層廚房的排水橫干管布置在一層天花板下,分別排入建筑東側的市政污水管網中,底層衛生間的污廢水單獨排出。排水立管與墻壁、柱等表面凈距為30mm;排水管與其他管道共同埋設時,水平凈距為1.0~3.0m,豎向凈距為0.15~0.20m。排水管道的固定措施:立管用管卡,最大間距為3.0m,每層至少設一個,在呈插管接頭處宜設置管卡,橫管一般采用管箍,最大間距為1.0m。立管穿越樓層時,預留孔洞為:D+50mm~100mm。
排水系統設計計算
3.2.1 設計秒流量公式:
=
式中,------計算管道衛生器具最大流量,L/S
-----建筑物用途系數,取2.0
3.2.2排水系統水力計算
如表1、2。
4 結語
通過上面實例的分析,大家可以看出房屋排水工程設計是一項十分繁瑣的過程,但也是為了人們日常生活方便必不可少的一步,目前我國對工程中的排水設計日益重視,希望排水工程的設計可以越來越成熟。
參考文獻
[1]《建筑給排水設計手冊》.
[2]《建筑給排水設計規范》(GBJ15—88).
[3]《室內給排水工程》.
[4]《建筑給排水工程》.
[5]《高層建筑給排水工程》.