摘 要:介紹了國產600 MW 超臨界機組快減負荷功能 (Run back,簡稱RB)試驗的情況,對試驗成功的經驗進行了總結,為同類型機組進行RB試驗提供了參考。通過RB試驗,對發現的問題以及相關控制策略進行了修改和完善。
關鍵詞:超臨界機組 協調控制 RB
中圖分類號:TH-39 文獻標識碼:A 文章編號:1674-098X(2011)03(c)-0004-03
Test Research on RB Function for 600 MW Supercritical Generating Units
ZHANG Ya-qiang1,WANG Tie-lin2,TANG Yang-wen2
(Jiangsu Guohua Chenjiagang Power Generation Co. , Lt d. ,City Yancheng 224631,China)
Abstract:Introduced the domestically produced 600 MW supercritical generating units Run back (Run back,Short RB) experiments,to experimented the successful experience to carry on the summary,carried on the RB experiment for the same type generating unit to provide the reference.Through the RB experiment,it has made the revision and the consummation to the discovery question as well as the correlation control strategy.
Key words:Supercritical generating Unit;Coordination control;RB
RB試驗的主要目的是檢驗火電機組在重要輔機發生故障跳閘,鍋爐出力低于給定功率時,自動控制系統將機組負荷快速降低到其實際所能達到的相應出力的能力,是對機組自動控制系統性能和功能的一項重要考驗。RB試驗不僅是檢驗協調控制系統在重要輔機故障跳閘后的抗干擾能力,而且通過RB試驗可對各控制回路進行調整和優化,使熱控系統在最佳工況下運行,從而實現機組的全程負荷控制。
某電廠二期工程的5、6號機組為擴建600 MW超臨界機組。鍋爐為上海鍋爐廠生產的SG-1913/25.4-M957型鍋爐,為超臨界參數變壓直流鍋爐,四角切向燃燒方式,一次中間再熱,平衡通風,固態排渣,露天布置,全鋼構架,全懸吊結構,“P”型直流鍋爐。汽輪機由上海汽輪機廠生產,型號為N600-24.2/566/566型600MW超臨界中間再熱凝汽式汽輪機。發電機由西門子公司生產,型號為THDF118/56型三相同步汽輪發電機。機組的熱控系統包括:MCS、SCS、DAS、FSSS、ETS、ECS、DEH等控制功能,DEH與DCS一體化,全部采用美國MAMC公司的MaxDNA分散控制系統。機組在168 h試運后進行了RB功能試驗,并取得了成功,為機組投產后的長周期、安全、穩定運行打下了良好的基礎。
1 機組試驗前具備的條件
(1)試驗前機組模擬量控制系統,如功率控制系統、燃燒控制系統、給水控制系統、溫度控制系統和其它輔助控制系統正常投入,并經過相應的定值擾動和負荷變動試驗,調節品質達到驗評標準的要求?!?br>