摘 要:室內環境溫濕度是空調系統的兩個主要參數,對其及時、準確測量是設計變風量空調風口形式的一個重要依據。介紹由單片機AT89C52和數字式、單總線型溫度傳感器DS18B20以及溫濕度傳感器SHT11組成的多點測量系統。采用28個DS18B20組成矩形測溫網絡,3個SHT11組成溫濕度測量部分,有效地改善了系統的測控能力,為風口形式的設計提供了研究平臺。 關鍵詞:變風量空調系統; 室內溫濕度;AT89C52;DS18B20; SHT11
中圖分類號:TN919-34文獻標識碼:A
文章編號:1004-373X(2010)18-0154-03
Multi-parameter Measurement Method for Variable Air Volume Air-conditioning System
YANG Ting, YAN Jie
(College of Mechanical Electrical Engineering, Xi’an University of Architecture Technology, Xi’an 710055, China)
Abstract: Temperature and humidity in indoor environment are two main parameters of an air-conditioning system, for which the accurate measurement is a basis of designing the type of the VAV air-conditioning vent. A multi-point measurement system composed of singal chip microcontroller AT89C52, single-bus category digital sensor DS18B20 and temperature / humidity sensor SHT11 is introduced. This system includes a rectangle temperature detecting network with 28 DS18B20 sensors and a temperature / humidity measurement section with 3 SHT11 sensors, which efficiently improve the measurement and control ability of this system, and offer a research platform for designing the vents of VAV air-conditioning systems.Keywords: variable air volume air-conditioning system; temperature / humidity in indoor environment; AT89C52; DS18B20; SHT11
0 引 言
變風量空調系統是利用改變送入空調區域的送風量來適應區域內負荷變化的一種空調系統。它不僅能提供良好的舒適性,而且有顯著的節能效果,因此獲得了廣泛的應用。變風量空調系統是靠變風量末端來實現的,而控制變風量末端設備的依據是室內空調參數,合理準確地測量室內參數是實現控制的基本保證。因此要成功實現變風量空調系統風口結構的優化設計,及時、準確的測控環境溫度是關鍵。
隨著信息技術革命的深入和計算機技術的飛速發展,各種先進技術都應用于VAV系統中,對溫濕度檢測技術的要求也愈來愈高。傳統對變風量空調實驗室變風量末端裝置的研究依據是采用傳統的分立式溫度傳感器熱電偶作為傳感器的測溫系統,測量時存在零點補償問題,且外圍電路復雜,體積較大,其轉換數據不易用計算機處理,而通常傳統模擬濕度傳感器不僅要設計信號調理電路,還要經過復雜的校準和標定過程,其測量精度難以保證。……