姜永偉



摘要 ? ?本文研究了國內外標準對含細菌水樣保存時間的規定,4 ℃和10 ℃條件下開展了低、中、高3個濃度水樣連續24 h條件試驗。結果表明,4 ℃和10 ℃條件下,24 h內測定細菌總數的結果在統計學意義上無顯著性差異;4 ℃條件下,24 h內中濃度水樣細菌總數計數結果在統計學意義上無顯著性差異;低濃度和高濃度水樣有顯著性差異。建議水樣的保存時間不宜超過6 h。
關鍵詞 ? ?含細菌水樣;保存時間;條件試驗;淡水水體
中圖分類號 ? ?X832 ? ? ? ?文獻標識碼 ? ?A
文章編號 ? 1007-5739(2020)15-0182-02 ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 開放科學(資源服務)標識碼(OSID)
Abstract ? ?The domestic and international standards for the preservation time of water samples containing bacteria were studied. The 24 h continuous condition test of water samples with low, medium and high concentrations were carried out at 4 ℃ and 10 ℃. The results showed that there was no significant difference in the total bacteria in 24 hours between 4 ℃ and 10 ℃. At 4 ℃,there was no significant difference in the total bacteria in the medium concentration samples within 24 hours, but there were significant differences between low concentration and high concentration samples. It is suggested that the preservation time of water sample should not exceed 6 hours.
Key words ? ?water sample containing bacteria; preservation time; condition test; fresh water
《水質 細菌總數的測定 平皿計數法》(HJ 1000—2018)[1]中規定,細菌總數是指36 ℃培養48 h,樣品在營養瓊脂上所生長的需氧菌和兼性厭氧菌菌落總數。在水環境微生物檢測中,由于細菌繁殖速度快,含細菌的水樣保存時間限制成為遠距離運輸難以克服的困難。
國內外標準對于水樣的保存時間多規定在6 h以內(表1),個別標準如 《水質-大腸桿菌和大腸菌群的計數-最大可能數法》(ISO 9308-2—2012)[2]將時間延長至18 h。為驗證細菌樣品的最大保存時間,本文選取低、中、高3個濃度水樣,在4 ℃和10 ℃保存溫度下,開展了1次/h、連續24 h的條件試驗。
1 ? ?試驗方法
就近采集低濃度、中濃度和高濃度3個濃度水樣,充分混勻后分裝于一系列樣品瓶內,然后分別放置在4 ℃和10 ℃冰箱中冷藏保存,每小時取1瓶水樣,混勻后用平皿計數法在無菌操作間中接種并培養48 h后,計數平皿上生長的細菌菌落總數。
2 ? ?結果與分析
48 h平皿上生長的細菌菌落總數結果見表2。同時,將以上結果經對數處理后進行配對T檢驗,結果見表3。
由表3可見,在4 ℃和10 ℃條件下,低、中、高3種濃度下24 h內測定細菌總數的結果在統計學意義上無顯著性差異(P=0.334、P=0.611、P=0.297)。
在4 ℃保存條件下,選取低、中、高3種濃度細菌總數結果差異最大的不同時間段的值經對數處理后進行配對T檢驗,結果見表4。
結果表明,4 ℃條件下,24 h內中濃度水樣細菌總數計數結果在統計學意義上無顯著性差異(P=0.163);低濃度和高濃度水樣有顯著性差異(P=0.000、P=0.001)。
3 ? ?結論與討論
試驗結果表明,4 ℃和10 ℃條件下,24 h內測定細菌總數無顯著差異;本試驗中,4 ℃條件下,中濃度水樣低溫保存24 h后無顯著差異,但是基于日常檢測中水樣濃度的未知性和歷史數據的延續性(國內標準對含細菌水樣的保存時間均為6 h),建議水樣保存時間不宜超過6 h[9-10]。
4 ? ?參考文獻
[1] 生態環境部.水質 菌落總數的測定 平皿計數法:HJ 1000-2018[S].北京:中國環境出版社,2018.
[2] International Organization for Standardization.Water quality-enumeration of Escherichia coli and coliform bacteria-Part 2:Most probable number method:ISO 9308-2-2012[S/OL].(2020-07-01)[2020-01-04].https://www.iso.org/standard/52246.html.
[3] United States Environmental Protection Agency.Monitoring methods of water and wastewater environmental microorganism:EPA-HQ-OW-2013[S/OL].(2013-07-07)[2020-01-04].https://www.epa.gov/laws-regulat-ions/laws-and-executive-orders.
[4] European Norm.Water quality-detection and enumeration of Escherichia coli coliform bacteria-Part 1:Membrane filtration method:ISO 9308-1:2000 [S/OL].(2001-07-01)[2020-01-04].https://www.scirp.org/reference/ReferencesPapers.aspx?ReferenceID=1101476.
[5] APHA.Standard analytical methods for water and waste water:APHA 9215-2012[S/OL].(2016-01-19)[2020-01-04].https://www.scirp.org/reference/ReferencesPapers.aspx?ReferenceID=2333411.
[6] 中華人民共和國環境保護部.水質 總大腸菌群和糞大腸菌群的測定 紙片快速法:HJ 755-2015[S].北京:中國環境科學出版社,2015.
[7] 國家環境保護總局.環境監測技術規范[M].北京:中國環境出版社,1986.
[8] 國家環境保護總局《水和廢水監測分析方法》編委會.水和廢水監測分析方法[M].4版.北京:中國環境科學出版社,2002.
[9] 陸慧慧,陸茸.關于國標中氨氮水樣保存方法的探討[J].北方環境,2012,24(3):169-170.