摘 要:為達到自動監控渠道水量和流量的目的,本文利用SCL-83便攜式流量計對安裝于南水北調中線干渠分水閘處的超聲波流量計進行了流量率定,依據SCL-83便攜式流量計實測的流量與分水閘處超聲波流量計流量擬合相關關系模型,并對相關關系進行三性檢驗和誤差分析。分析結果表明,所建立的相關關系滿足定線整編的規范要求,具有良好的代表性,達到了流量計精度改善和提高準確性的目的。
關鍵詞:流量率定;分水閘流量計;SCL-83便攜式流量計
中圖分類號:TH814.92 文獻標識碼:A 文章編號:1003-5168(2019)32-0090-03
Application?of?SCL-83?Portable?Flowmeter?in?the?Calibration?of?Flow
Meter?of?Water?Distribution?Gate
HAO?Jinyi LUO?Chengyan ZHANG?Zongmin XIAO?Bowen
(Hanjiang?Hydrology?and?Water?Resources?Survey?Bureau,?Hydrology?Bureau?of?Changjiang?Water?Resources?Commission,Xiangyang?Hubei?441022)
Abstract:?In?order?to?achieve?the?purpose?of?automatically?monitoring?channel?water?volume?and?flow,?this?paper?used?the?SCL-83?portable?flowmeter?to?determine?the?flow?rate?of?the?ultrasonic?flowmeter?installed?at?the?main?channel?branch?of?the?South-to-North?Water?Transfer?Project,?and?fited?a?correlation?model?according?to?the?measured?flow?of?the?SCL-83?portable?flowmeter?and?the?flowmeter?of?the?ultrasonic?flowmeter?at?the?sub-slug,?and?performed?a?sex?test?and?error?analysis?on?the?correlation.?The?analysis?results?show?that?the?established?correlations?meet?the?requirements?of?the?alignment?of?the?alignment,?have?good?representation,?and?achieve?the?purpose?of?improving?the?accuracy?and?accuracy?of?the?flowmeter.
Keywords:?flow?rate?setting;water?flow?meter;SCL-83?portable?flow?meter
SCL-83便攜式流量計是唐山匯中儀表股份有限公司研制生產的一種采用外夾式多聲路換能器測量封閉管道內液體流量的儀表,是以傳播速度差法(時差法)為基本原理的超聲波流量測量儀表。該儀表由測量主機、SCL流量顯示分析儀、換能器及緊固裝置等部分組成。該流量計具有不需要停水安裝、安裝操作簡便、測量精度高、對各種復雜流態適應性強、可連續工作時間長等優點。
測量介質是充滿被測管道的水、污水及其他均質液體(懸浮含量≤10g/L),測量管徑為80~2?000mm,測量流速范圍為0.2~12.0m/s,準確度達到0.5級。該流量計符合《給排水用超聲波流量計》(CJ/T?3063—1997)、《管道式電磁流量計在線校準要求》(CJ/T?364—2011)、《超聲流量計》(JJG?1030—2007)的要求。
2018年,利用國家認定并經過質檢部門鑒定后的SCL-83便攜式流量計對安裝于南水北調中線干渠的某分水閘處的超聲波流量計進行了率定,并通過所建立的數學模型對分水閘處的超聲波流量計進行了必要的修正,對測驗資料及成果進行分析與整編,以期改善分水閘處流量測驗成果,得到高精度自動監控渠道水量和流量。……