李磊 吳叢 李文濤 劉洋銘 劉超

摘 要:在使用過程中,家用空調直流電機會出現軸響問題。本文從軸響故障電機失效模式、失效機理、生產過程管控及檢測方式可靠性等方面進行分析。同時,通過直流變頻電機工作原理分析和不同條件下故障模擬復現,找出電機軸承存在的缺陷,并從電機本身可靠性著手,結合檢測方式的創新與完善,提升直流電機的運行可靠性。
關鍵詞:直流電機;軸承電腐蝕;端部感應電壓;軸電流
中圖分類號:TM33;TM925.12 文獻標識碼:A 文章編號:1003-5168(2019)32-0058-03
Research?and?Application?of?Electric?Corrosion?of?DC?Motor
Bearings?for?Air?Conditioning
LI?Lei WU?Cong LI?Wentao LIU?Yangming LIU?Chao
(Gree?Electric?Appliances,?Inc.of?Zhengzhou,Zhengzhou?Henan?450001)
Abstract:?In?the?process?of?use,?the?problem?of?shaft?noise?will?occur?in the?DC?motor?of?the?household?air?conditioner.?This?paper?analyzed?the?failure?mode,?failure?mechanism,?production?process?control?and?detection?method?reliability?of?the?shaft?response?fault?motor.?At?the?same?time,?through?the?analysis?of?the?working?principle?of?the?DC?variable?frequency?motor?and?the?fault?simulation?reproduction?under?different?conditions,?the?defects?existing?in?the?motor?bearings?were?found,?and?started?from?the?reliability?of?the?motor?itself,?combined?with?the?innovation?and?improvement?of?the?detection?method,?the?operation?reliability?of?the?DC?motor?was?improved.
Keywords:?continuous?current?dynamo;electrocorrosion?of?bearing;end?induced?voltage;shaft?current
直流電機目前被普遍應用在家用空調領域,基于其變頻的優點,被更多地應用在高端家用空調機型上。隨著生活水平和品質要求的提高,用戶對空調噪聲也有一定的要求。根據市場用戶反饋,使用過程中出現了不同程度的噪聲問題。
1 事件背景
據不完全統計,2018年至今,售后市場陸續反饋,某廠家電機在終端市場使用過程中存在噪聲問題,主要集中在后軸承室內部。因此,筆者對多次反饋的同廠家編碼電機同區域噪聲異常進行調查分析和驗證。
2 問題分析
2.1 故障舊件復核確認
對售后返回舊件進行重新裝機驗證(5臺),試機時發現,電機后端蓋有明顯軸承噪聲,裝機驗證5臺,軸承噪聲及位置基本一致。利用低電阻測試儀對退回電機外部接線片接觸電阻進行測試,接地電阻均較大(125mΩ、150?mΩ、無窮大等),測試時時常出現不穩定、阻值跳動及無窮大等現象。
對接地電阻無窮大電機進行手工用力測試,結果發現,用力程度不同,接線片與后端蓋存在時通時不通現象。……