新能源電源故障暫態(tài)特性研究

2016-05-30 00:36:07畢天姝劉素梅薛安成楊奇遜
科技創(chuàng)新導(dǎo)報(bào) 2016年10期
關(guān)鍵詞:新能源故障

畢天姝 劉素梅 薛安成 楊奇遜

摘 要:以風(fēng)電、光伏發(fā)電為代表的新能源電力發(fā)展迅猛,其對(duì)電力系統(tǒng)保護(hù)與安全的影響不容忽視。然而由于風(fēng)電、光伏發(fā)電等新能源電源與傳統(tǒng)火電電源相比,在發(fā)電機(jī)理、并網(wǎng)方式與運(yùn)行控制技術(shù)等方面有較大差異,導(dǎo)致新能源電源的故障暫態(tài)特性難以用已有方法分析研究。為此,針對(duì)目前兩大類主流的新能源電源包括全功率變換器型(永磁直驅(qū)風(fēng)力發(fā)電機(jī)組和光伏電池組件等)和部分功率變換器型(雙饋風(fēng)力發(fā)電機(jī)組)電源,研究其故障暫態(tài)特性對(duì)于開展大規(guī)模新能源電源接入電網(wǎng)后保護(hù)適應(yīng)性評(píng)估及繼電保護(hù)新原理研究具有重要意義。針對(duì)全功率變換型能源電源,分析了故障位置、故障類型、電源本體輸入功率及接入臺(tái)數(shù)、故障期間有功和無功功率支撐水平,以及所接電網(wǎng)短路容量等對(duì)其對(duì)稱與不對(duì)稱故障暫態(tài)特性的影響規(guī)律,全面揭示了該類型電源的故障暫態(tài)特性。在故障發(fā)生及切除后的暫態(tài)過程中全功率變換型能源電源提供的故障電流會(huì)在短時(shí)間內(nèi)迅速上升或下降,且包含較大直流、二倍和三倍基頻諧波量。在故障期間的準(zhǔn)穩(wěn)態(tài)過程中,全功率變換型電源將可能運(yùn)行于并網(wǎng)控制和低電壓穿越控制兩種模式。在出口電壓跌落較嚴(yán)重、直流輸入功率較大、所接系統(tǒng)短路容量較小時(shí),低電壓穿越控制將更易起作用。在低電壓穿越控制模式下電源輸出故障相電流的最大值等于變換器最大允許電流(一般為1.5~2 pu,同步發(fā)電機(jī)所提供故障電流約為5~10 pu)。而運(yùn)行于并網(wǎng)控制模式下的電源輸出的故障電流小于2 pu,大小由直流輸入功率、出口處電壓變化程度及功率因數(shù)決定。針對(duì)部分功率變換型能源電源,分析了故障發(fā)生時(shí)刻、故障位置、故障類型、風(fēng)速、故障期間無功功率支撐水平等對(duì)其對(duì)稱與不對(duì)稱故障暫態(tài)特性的影響規(guī)律,從而揭示了該類型電源在故障下的電磁暫態(tài)特性。在故障發(fā)生及切除初始階段,由于電網(wǎng)電壓突變,該電源輸出電流中將包含較大的接近直流的衰減分量和負(fù)序分量(不對(duì)稱故障),這些電流分量主要由雙饋發(fā)電機(jī)本身的暫態(tài)響應(yīng)特性決定。故障發(fā)生或切除一段時(shí)間后,隨著定子磁鏈直流分量的衰減,且由于轉(zhuǎn)子勵(lì)磁變換器控制逐漸發(fā)生作用,該電源的故障暫態(tài)特性將不僅受雙饋發(fā)電機(jī)本身故障暫態(tài)響應(yīng)特性影響,還會(huì)受到轉(zhuǎn)子勵(lì)磁變換器的控制影響。故障后穩(wěn)態(tài)階段,該新能源電源的故障特性主要與其運(yùn)行控制模式有關(guān),包括正常并網(wǎng)運(yùn)行控制模式和低電壓穿越運(yùn)行兩種模式。在不同運(yùn)行模式下,部分功率變換型電源輸出的故障電流不同,但故障穩(wěn)態(tài)電流的最大值不超過額定電流值的3倍。

關(guān)鍵詞:全功率變換型新能源電源 部分功率變換型新能源電源 電磁暫態(tài)模型 故障特性

Abstract:The penetration of renewable energy sources, especially for wind power and photovoltaic, is increasing rapidly in recent years. As a result, these renewable generators (RGs) have greatly affected the existing protection. As compared with the traditional synchronous generators, the RGs are different on the electricity generation principles, integration topology and control mode, which make their fault behaviors change accordingly. Therefore, the conventional fault analysis method can not be used for estimating the fault contribution of RGs. Hence, the fault characteristics are studied systematically for two main types of RGs, i.e. full- and partial-rated converter interfaced RGs. For full-rated converter interfaced RGs, the impact factors on their symmetrical and asymmetrical fault characteristics are thoroughly studied, such as fault locations and types, dc input power and rated capacity of the RGs, real and reactive power level delivered to grid, and so on. After fault occurrence and its clearance, the fault current from RGs quickly increases (decreases), and include abundant harmonious like dc component, 100 Hz and 150 Hz frequency components. During the faulty steady period, the fault characteristics of RGs are decided by the normal integration control or fault ride through (FRT) control. With the action of FRT control, the maximum faulty current from RGs is limited within the inverters ampere constraint (generally 1.5~2 pu). If the normal integration control is employed, the fault current is always less than the constraint, and calculated by dc input power, the dip depth of grid voltage and power factors at the inverter pole. For partial-rated converter interfaced RGs, the main impact factors on their balanced and unbalanced fault behaviors are also systematically analyzed, including fault occurrence times, fault locations an types, wind speed and so on. During the transient process of fault occurrence and its clearance, due to the voltage dip, the fault current of RGs includes larger near-dc and negative-sequence component. These components are mainly influenced by the transient behaviors of doubly fed induction generators (DFIGs). After the transient periods, as the dc component of stator flux is exponentially damping, the fault characteristics of RGs are related to the transient responses of DFIG and its control mode. During the plateau periods of faults, the fault characteristics are determined by the converters control mode.

Key Words:Full-rated converter interfaced renewable generator;Partial-rated converter interfaced renewable generators;Electromagnetic model;Fault characteristic

閱讀全文鏈接(需實(shí)名注冊(cè)):http://www.nstrs.cn/xiangxiBG.aspx?id=51124&flag=1

猜你喜歡
新能源故障
63%新能源二手車開不滿5萬(wàn)公里就被賣掉
故障一點(diǎn)通
新能源汽車成為主流還需要多久?
海峽姐妹(2019年8期)2019-09-03 01:01:00
買不買新能源汽車
奔馳R320車ABS、ESP故障燈異常點(diǎn)亮
故障一點(diǎn)通
故障一點(diǎn)通
故障一點(diǎn)通
江淮車故障3例
“新能源門”的背后
風(fēng)能(2015年4期)2015-02-27 10:14:36
主站蜘蛛池模板: 毛片视频网| 伊人天堂网| 欧美成人影院亚洲综合图| 亚洲国产清纯| 999国内精品视频免费| 超碰免费91| 999国内精品视频免费| 成人福利在线免费观看| 久久天天躁夜夜躁狠狠| 999国产精品| 最新日韩AV网址在线观看| 国产一区二区精品高清在线观看| 亚洲丝袜中文字幕| 成人福利在线视频免费观看| 国产高潮视频在线观看| 无码一区18禁| 久久精品一品道久久精品| 国产精品无码AⅤ在线观看播放| 亚洲天堂网在线播放| 国产免费久久精品99re丫丫一| 免费一级大毛片a一观看不卡| 亚洲一区网站| 亚洲五月激情网| 色网站在线视频| 免费在线国产一区二区三区精品| 久久午夜夜伦鲁鲁片不卡| 91欧美亚洲国产五月天| 欧美日韩国产综合视频在线观看 | 中文字幕永久视频| 国产精品亚洲精品爽爽| 国产91高清视频| 亚洲国产精品日韩欧美一区| 青青青视频免费一区二区| 国产理论一区| 午夜啪啪福利| 中国精品久久| 午夜色综合| 亚洲品质国产精品无码| 一级不卡毛片| 97色伦色在线综合视频| 伊人色天堂| 欧美区一区二区三| 色网站免费在线观看| 欧美成人综合视频| 拍国产真实乱人偷精品| 欧美在线视频不卡| 97在线碰| 一级成人欧美一区在线观看| 亚洲美女一区二区三区| 欧美亚洲一区二区三区导航| 老汉色老汉首页a亚洲| 无码福利日韩神码福利片| 日本福利视频网站| 成人在线视频一区| 91在线无码精品秘九色APP| 中文字幕乱码二三区免费| 狠狠干综合| 久久久精品久久久久三级| 在线观看国产网址你懂的| 色综合天天综合中文网| 欧美a级完整在线观看| 制服丝袜 91视频| 成人国产精品2021| 91麻豆精品国产高清在线| 欧美国产精品拍自| 国产在线第二页| 4虎影视国产在线观看精品| 在线播放91| 亚洲欧洲日本在线| 国产白浆一区二区三区视频在线| 欧美亚洲国产精品第一页| 欧美精品综合视频一区二区| 欧美三级自拍| 欧美精品在线免费| av在线无码浏览| 99久久国产自偷自偷免费一区| 精品欧美一区二区三区久久久| 欧美成人精品在线| 无码日韩人妻精品久久蜜桃| av无码一区二区三区在线| 中文字幕人妻av一区二区| a毛片基地免费大全|