A Novel Aircraft Air Conditioning System with a Sterilization Unit by Ultra-High-Temperature Air Stream

2020-09-16 01:13:36,2,*,

,2,*,

1.Key Laboratory of Aircraft Environment Control and Life Support,MIIT,Nanjing University of Aeronautics and Astronautics,Nanjing 210016,P.R.China;2.College of Civil Aviation/College of Flight,Nanjing University of Aeronautics and Astronautics,Nanjing 211106,P.R.China

(Received 10 March 2020;revised 5 July 2020;accepted 14 July 2020)

Abstract: An aircraft cabin is a narrow,closed-space environment. To keep the air quality in cabin healthy for passengers,especially during an epidemic such as SARS-CoV-2(or 2019-nCoV)in 2020,a novel aircraft air conditioning system,called the ultra-high-temperature instantaneous sterilization air conditioning system(UHTACS),is proposed. Based on the proposed system,a simulation of the UHT-ACS is analysed in various flight states.In the UHT-ACS,the mixing air temperature of return and bleed air can reach temperature up to 148.8 ℃,which is high enough to kill bacilli and viruses in 2―8 s. The supply air temperature of the UHT-ACS in a mixing cavity is about 12 ℃in cooling mode,both on the ground and in the air. The supply air temperature is about 42 ℃in heating mode. Compared with the air conditioning systems(ACS)of traditional aircraft,the supply air temperatures of the UHT-ACS in the mixing cavity are in good agreement with those of a traditional ACS with 60% fresh air and 40%return air. Furthermore,the air temperature at the turbine outlet of the UHT-ACS is higher than that of a traditional ACS,which will help to reduce the risk of icing at the outlet. Therefore,the UHT-ACS can operate normally in various flight states.

Key words:air conditioning system (ACS) ; ultra-high-temperature instantaneous sterilization; ultra-hightemperature instantaneous sterilization air conditioning system(UHT-ACS);return air;2019-nCoV

0 Introduction

With the development of civil aviation,more and more people are choosing air transportation for mid- and long-range travel. In recent years,the number of civil aviation flights has increased significantly. During a flight,the health and safety of passengers is an important issue to be considered because they must stay in a small,enclosed cabin environment for long periods. Therefore,the aircraft air conditioning system is an important mechanism for providing a healthy air atmosphere for passengers. It achieves this by adjusting the parameters of the cabin environment,such as pressure,temperature and humidity.

To date,the spread of viruses has become more frequent and severe,such as SARS in 2003,H1N1 in 2009,Ebola and SARS-CoV-2(or 2019-nCoV)in 2020[1-2]. The high infectivity and fatality rate of these viruses make people reluctant to take public transportation during an epidemic. With the most recent epidemic,airlines have had to cancel thousands of flights and all airline carriers are suffering deep financial losses. In flight,much of the infection risk comes from the mouths,noses and hands of passengers sitting close to one another. To decrease the risk,it becomes a matter of wearing adequate personal protective equipment, such as masks,protective cover,clothing and gloves,and refraining from eating and drinking for several hours. Therefore,the air quality in the cabin is related to the health and safety of passengers. How to defend passengers from infection during an epidemic becomes an urgent task for aircraft air conditioning systems(ACS).

The disinfection and sterilization of air conditioning systems have applied mainly to the architectural field[3-4]. Yanagi et al.[5]reported experimental results on the sterilization effect of ozone on microorganisms,including the“exposure intensity”for the required sterilization time. LYU et al.[6]studied the microwave sterilization of biological pollution in the central air conditioning systems of buildings and found that microwave radiation at a power of 900 W was ideal for reaching an effective sterilization temperature(50―59 ℃)within 5 min. Li et al.[7]found that the inner dust weight of air conditioning pipes was high and that microbial pollution was serious.TiO2was used as a photocatalyst purification mechanism for killing microorganisms on air duct surfaces in a timely manner. Shi et al.[8]developed a complete set of intelligent cleaning-sterilizing equipment for the ventilation ducts of an air-conditioned passenger train. However,the investigations of aircraft air conditioning systems have focused mainly on cooling and heating performance.Wang[9]and Shu et al.[10]simulated the performance of traditional aircraft air conditioning systems. Nan et al.[11]and Wu[12]analysed the recirculation systems on civil aircraft. Sun et al.[13-14]developed a Bayesian failure prognostics approach using airplane condition monitoring system(ACMS)data for the predictive maintenance of air ACS. They proposed a novel health indicator extraction method based on available sensor parameters for the health monitoring of the ACS on a legacy commercial aircraft model. The method can identify the ACS failure precursors in advance with the relative errors of less than 8%. The proposed method was validated on a single-aisle commercial aircraft,which was widely used for medium-haul routes. Tu et al.[15]provided a new method for the dynamic simulation of aircraft environmental control systems(ECS). The method was demonstrated by performing steady-state and dynamic analyses in dry and wet operating conditions. Jennions et al.[16]proposed a simulation framework called the Simscape environmental control system simulation under all conditions(SESAC). It simulated the health state indicating parameters at the subsystem and component levels under a wide range of aircraft operating scenarios. Tfaily et al.[17]presented an integration considering environmental control and ice protection systems,compared the multidisciplinary design optimization(MDO)results obtained with and without the considered air systems,and demonstrated the impact on optimal aircraft design. Li et al.[18]and Sun et al.[19]used failure mode and effects analysis(FMEA)and hierarchy multi-signal flow to diagnose faults in an aircraft ACS. Moreover,simulation of the transportation of passengers in an aircraft cabin is also an important topic. Liu et al.[20]explored the interpersonal exposure to exhaled droplets and droplet nuclei of two standing thermal manikins. He found a substantial increase in airborne exposure to droplet nuclei exhaled by the source manikin when a susceptible manikin is within about 1.5 m of the source manikin. Lin et al.[21]studied the transmission law of respiratory pathogens through the breath of sick passengers in an aircraft cabin to reduce the risk of infection by the numerical modelling of a Boeing 737 economy cabin. The susceptible-exposed-infectious(SEI)model was taken as an evaluation index for the risk of infection for other passengers. Jan et al.[22]studied the dependency between the type of air distribution system and indoor air quality in the cabin of a small transport aircraft.Three types of air distribution system were investigated by computational fluid dynamics(CFD). The results showed that the most stable air distribution was attained with a modified mixing air distribution system. Sun et al.[23]suggested an improved evaluation index called the predicted mean vote for fighter(PMV_F)to measure the thermal comfort in an aircraft cabin. The flow and temperature fields of the cabin were simulated. Farag et al.[24]studied a ventilation system with both underfloor displacement and personalized ventilation(PV)with GB injection in the aircraft cabin of the economy section of a Boeing 767 airplane during cruising. They also studied the protection of passengers by air curtains designed for different states. They found that an air curtain was effective for preventing the spread of GB,but of course this also increased the temperature and decreased thermal comfort inside the aircraft cabin.

In civil aircraft,recirculation air is used in ACSs. Although ACSs have high-efficiency particulate air(HEPA)filters,this is still a great threat to passengers’health during the epidemic,especially on long flights. To solve the problem,a new aircraft ACS is proposed in this paper. It uses an ultra-hightemperature instantaneous sterilization method. The method has been proven useful and effective under various conditions both on the ground and in flight.

1 Ultra-High-Temperature Instantaneous Sterilization Air Conditioning System

It is known that if temperature reaches 135―150 ℃,bacilli and viruses can be killed within 2―8 s[25]. Therefore,in order to sterilize and kill viruses in the return air of an ACS,a new system called the ultra-high-temperature instantaneous sterilization air conditioning system(UHT-ACS)[26]is described in this paper. The system schematic diagram is shown in Fig.1. Compared with a traditional ACS,a high-temperature sterilization recirculation subsystem pipeline is added in the UHT-ACS. The working principle of the UHT-ACS is that the recirculated air is mixed with high-temperature bleed air from the engine. Thus,the recirculated air temperature will become sufficiently high and virus and bacteria will be killed within one second in the hightemperature mixing cavity. Specifically,during an epidemic such as 2019-nCov,H1N1 or another influenza virus,the UHT-ACS can work. The traditional recirculation sub-pipeline is shut down,and a high-temperature sterilization recirculation sub-pipeline is opened. The recirculated air is transported to the high-temperature mixing cavity by a fan. Then,it is mixed with the high-temperature bleed air from the engine though an ejector in the mixing cavity.After mixing,the gas temperature is high enough to kill viruses and sterilize the air. The mixing air is cooled by the ACS. Then the temperature is adjusted to one that is suitable to supply to the cabin.

Fig.1 Ultra-high-temperature instantaneous sterilization air conditioning system

2 Calculation Model

2.1 Heat exchanger

The heat exchanger is the main heat transfer component in the system. High-temperature air enters the hot side and cold air enters the cold side. Its heat exchange equation is given by

wheremis the mass of the heat exchanger,Cpthe specific heat of the fluid,igthe phase transformation enthalpy,dthe humidity ratio of the air,andhthe convective heat transfer coefficient. The subscript“w”denotes the wall parameter of the heat exchanger,the subscript“win”denotes the inner wall parameter of the heat exchanger and the subscript“wout”denotes the outer wall parameter of the heat exchanger. In addition,the subscript“h”denotes hot fluid,the subscript“cold”denotes cold fluid,the subscript“in”denotes inlet and the subscript“out”denotes outlet.

The pressure loss of the heat exchanger consists of friction drag,additional pressure loss,and local pressure drop. The total pressure loss of the heat exchanger is

where Δp′ is the pressure loss inlet the core of the heat exchanger,Δp′ the pressure rise at the core outlet,Δpcfthe pressure loss in the core,and Δpathe local pressure drop at the connection. Meanwhile,σis the porosity of the heat exchanger,K′the pressure loss coefficient of the heat exchanger at the inlet,ωthe mass flow rate,v′ the specific volume,vmthe average of the specific volumes,fthe flow coefficient of the core,dethe equivalent diameter of the core,Lthe characteristic length of the core,K″the pressure loss coefficient of the heat exchanger at the outlet,ξthe local pressure drop coefficient at the connection,andν″the average of the specific volumes at the core outlet.

Truly the man would have had no objection to be rich, but he thought to himself: I must first ask my daughter about this, so he went in and told them that there was a great white bear outside who had faithfully promised to make them all rich if he might but have the youngest daughter

2.2 Compressor

The compressor is an important component in the UHT-ACS. As the compressor is working,its parameters change rapidly and the thermal inertia is small;therefore,it can be considered as an approximately steady-state process. According to the adiabatic change process of the compressor,the equation of the model can be given by

wherem1andm2are the mass flow rates in and out of the compressor,respectively;Nis the index of polytropic compression,ηvthe volume efficiency of the compressor,pcthe condensing pressure,pethe evaporating pressure,Vthe volume of the compressor,wthe work done by per kilogram of air in the compressor,hinthe enthalpy of the air at the compressor inlet,houtthe enthalpy of the air at the compressor outlet,ithe number of compressor cavities,Dthe diameter of the compressor,Sthe number of compressor strokes,andnthe rotational speed.

2.3 Turbine

In the ACS,the pressure and temperature of the air decrease sharply after expansion in the turbine. It becomes low-temperature air,which is used to cool the cabin. The flow,efficiency and speed characteristics are main performance characteristics of the turbine. Based on these characteristic curves,the model of the turbine is established,as follows[20]

whereηtis the adiabatic efficiency,πtthe expansion ratio,ηmthe torque efficiency,x0the speed ratio,Rethe Reynolds number of the gas in the turbine,kthe isentropic exponent and,λuthe velocity coefficient of the air.

2.4 Water separator

The water separator is used to remove the liquid phase water from the air. The temperature of the air passing through the water separator is basically unchanged. The water separation efficiency generally changes little for a given water separator. Therefore,it can be considered as a constant. Therefore,the pressure loss and humidity of air through the water separator can be given by

whereηwis the water separation efficiency(here,it is 0.9)andξthe drag coefficient(here,it is 0.8).

3 Results and Analysis

According to the previous simulation model,the ACS is analysed. Here,steady-state cooling with a traditional ACS is taken as an example. The ACS is taken is in a steady flight state with a flight altitude of 6.1 km,flight speed of 158 m/s and ambient air temperature of -25 ℃[10]. The simulation results are shown in Table 1. Compared with the experiment and computational data,it is found that the calculation results in this paper are in good agreement with Ref.[10].

The ultra-high-temperature instantaneous sterilization(UHT)system is built according to the system schematic diagram shown in Fig.1. Four typical cases are used for calculation and comparison with the traditional ACS. Cases 1 and 2 are the cases on the ground in summer and winter,respectively. Cases 3 and 4 are at the cruising altitude in summer and winter,respectively. The specific detailed parameters are shown in Table 2.

Table 1 Temperature and pressure of ACS simulation compared with experimental ones

Table 2 Parameters of ACS in calculation

In hot weather on the ground,the pressure and temperature change at various nodes by a traditional ACS and the UHT-ACS is shown in Fig.2.The temperatures at various component nodes are shown in Table 3. It can be seen that the air flow mass rate increases owing to the mixing of return air and bleed air in the UHT-ACS. The pressure in the working process of the UHT-ACS is higher than that of the traditional ACS. The temperature at the mixing air inlet of the ACS decreases to 148.8 ℃. The air temperature change trend is similar to that of the traditional ACS. After ACS,the temperature of air in the mixing cavity,which is supplied to the cabin,is 12.4 ℃.This is in the same region as the traditional ACS.Therefore,the UHT-ACS can meet the cooling demand of the aircraft in hot weather on the ground.

The simulation results of a traditional ACS and the UHT-ACS in cold weather,on the ground,are shown in Fig.3. The temperature of each component node is shown in Table 3. It can be seen that the pressure in the UHT-ACS is slightly higher than that in the traditional ACS. After ACS treatment,the air temperature in the mixing cavity of the traditional ACS is 42.4 ℃,whereas that in the UHT-ACS is 42.3 ℃. These are both consistent with the set supply air temperature of 42 ℃;therefore,the UHT-ACS can meet the heating demand of the aircraft in cold weather.

The simulation results of a traditional ACS and the UHT-ACS in hot weather,at an altitude of 9.45 km,are shown in Fig.4. The temperature of each component node is shown in Table 3. By comparison,it can be seen that the pressure in the system at high altitude is less than it is on the ground.This is caused by the low-pressure environment at high altitude. After treatment by the traditional ACS,the air temperature in the mixing cavity is 12.4 ℃and that of the UHT-ACS is 12.1 ℃. They are all consistent with the set supply air temperature of 12 ℃. Therefore,the UHT-ACS can meet the refrigeration requirements of the aircraft during flight in hot weather.

Fig.2 Pressure and temperature curves of different systems in hot weather on ground

Fig.3 Pressure and temperature curves of different systems in cold weather on ground

Table 3 Temperature at different nodes in traditional ACS and UHT-ACS ℃

Fig.4 Pressure and temperature curves of different systems in hot weather at an altitude of 9.45 km

The simulation results of a traditional ACS and the UHT-ACS in cold weather,at altitude of 12 km,are shown in Fig. 5. The temperature at each component node is shown in Table 3. It can be seen that the air temperature in the mixing cavity of the traditional ACS and that in the UHT-ACS are both 42.0 ℃. This is consistent with the set supply air temperature of 42 ℃. Therefore,the UHT-ACS and the traditional ACS can both be used for heating the cabin during flight in cold weather.

Comparing the outlet temperatures of the turbine in the refrigeration process,it is found that in the ground case the outlet temperature of the turbine of the traditional ACS is -14.8 ℃,whereas that of the UHT-ACS is -5.4 ℃. At the high-altitude case,the outlet temperature of the turbine if the traditional ACS is -16.9 ℃,whereas that with the UHT-ACS is 0.4 ℃. The higher turbine outlet temperature of the UHT-ACS helps to reduce the risk of icing at the turbine outlet. Therefore,the UHTACS is conducive to the normal operation of the system.

Fig.5 Pressure and temperature curves of different systems in cold weather at altitude of 12 km

4 Conclusions

A new ACS called the UHT-ACS was proposed in this paper. The system was calculated by simulation under various conditions. The results of the supply air temperature in the mixing cavity were in good agreement with the required set values in all cases.The main conclusions are as follows:

(1)In the UHT-ACS,the temperature of the mixing air can reach 148.8 ℃,which is sufficient to kill bacilli and viruses. Since the novel system simply modifies the existing air flow route,it does not complicate the design of air-conditioning system.

(2)The UHT-ACS can operate normally under various weather conditions while the aircraft is on the ground and during flight.

(3)The air temperature outlet the turbine of the UHT-ACS is higher than that of a traditional ACS,which helps to reduce the risk of icing at the turbine outlet.

This paper presents a novel aircraft sterilization air conditioning system,called the UHT-ACS. The UHT-ACS was compared with a traditional ACS in various steady conditions by simulation. The feasibility of the UHT-ACS was proven. However,the unsteady simulation of an entire flight is needed to analyse the burden and cost of the aircraft with the UHT-ACS. Therefore,the burden and cost of the aircraft with UHT-ACS,and the influence of the relevant parameters on the UHT-ACS should be studied in future works.

主站蜘蛛池模板: 欧美色99| 日韩高清中文字幕| 人妻无码中文字幕第一区| 日本中文字幕久久网站| 91精品视频在线播放| 亚洲色图欧美在线| 伦伦影院精品一区| 国产日韩精品欧美一区喷| 欧美视频二区| 97se亚洲综合| 99久久精品免费看国产免费软件| 婷婷六月激情综合一区| 91久久国产综合精品女同我| 精品少妇人妻av无码久久| 99精品视频九九精品| 亚洲色无码专线精品观看| 国产99欧美精品久久精品久久| 十八禁美女裸体网站| 日本道中文字幕久久一区| 五月丁香在线视频| 在线看免费无码av天堂的| 91在线精品免费免费播放| 日韩av无码精品专区| 一级一级一片免费| 国产乱人乱偷精品视频a人人澡| 亚洲综合狠狠| 成人午夜天| 久久这里只有精品国产99| 精品成人免费自拍视频| 亚洲综合片| 国产91丝袜| 国产在线精彩视频论坛| 免费网站成人亚洲| 婷婷五月在线| 91久久偷偷做嫩草影院电| 日韩东京热无码人妻| 香蕉精品在线| 久久人人97超碰人人澡爱香蕉| 国产精品久久久久久久久kt| 亚洲一区网站| 国产精品美人久久久久久AV| 日本黄色不卡视频| 国产中文一区a级毛片视频| 日韩专区欧美| 亚洲综合亚洲国产尤物| 日本伊人色综合网| 国产一级α片| 国产乱人免费视频| 国产美女主播一级成人毛片| 欧美日一级片| 四虎精品黑人视频| 夜夜操狠狠操| 无码高潮喷水在线观看| 老色鬼欧美精品| 人妻精品久久无码区| 欧美福利在线| 幺女国产一级毛片| 久草视频中文| 日韩av电影一区二区三区四区| 日韩精品欧美国产在线| 成年午夜精品久久精品| yjizz视频最新网站在线| 国产一区二区丝袜高跟鞋| 国产黑丝视频在线观看| 国产免费a级片| 国产网站免费看| 欧洲欧美人成免费全部视频| 亚洲AV无码乱码在线观看裸奔 | 欧美高清三区| 蜜桃臀无码内射一区二区三区| 国产国语一级毛片| 男人天堂亚洲天堂| 老司机精品99在线播放| 国产成人区在线观看视频| 波多野结衣一区二区三区四区视频 | 亚洲成人黄色网址| 白浆免费视频国产精品视频 | 日韩精品成人在线| 久久中文无码精品| 欧美精品另类| 国产一二三区在线| 国产自产视频一区二区三区|