【摘要】 付油計量裝置主要用于成品油的貿易計量,按照工作原理,主要分為容積法和質量法兩種計量方式。付油計量裝置準確與否,直接影響成品油進出庫計量的準確性,付油計量裝置檢定裝置可以檢測付油計量裝置的精度。本文基于容積法對付油計量裝置檢定裝置校準付油計量裝置的不確定進行評定,給出測量結果的不確定度。
【關鍵詞】 付油計量裝置;體積示值誤差;不確定度
【DOI編碼】 10.3969/j.issn.1674-4977.2018.01.004
Abstract:The Oil Dispensing Measuring Equipment is mainly used for the trade measurement of refined oil. According to the working principle, it is divided into two kinds of measurement methods: volumetric method and gravimetric method. The Oil Dispensing Measuring Equipment is accurate or not, directly affects the accuracy of refined oil measurement in and out storage, The Oil Dispensing Measuring Equipment verification equipment can detect Oil Dispensing Measuring Equipment.This article based on volumetric method to assess the uncertainty of the Oil Dispensing Measuring Equipment verification equipment calibration the Oil Dispensing Measuring Equipment, and gives the uncertainty of measurement results.
Key words:Oil Dispensing Measuring Equipment;Indication of volumetric;Uncertainty
付油計量裝置的檢測依據JJG(遼) 58-2011《付油計量裝置》進行。以付油計量裝置檢定裝置(以下簡稱“檢定裝置”)為標準器,通過付油計量裝置的油品容積與檢定裝置中的承載質量進行比較,經過溫度、密度修正到同一狀態下,即可確定被測付油計量裝置的示值誤差。
校準時將檢定裝置固定在被校準付油計量裝置的鶴位上,在正常付油工作流量點下進行校準,測量三次;校準前需將檢定裝置安裝調試好并自行校準,按操作手冊要求對檢定裝置進行預熱,使其與被檢測介質同溫;將被校準的付油計量裝置調試到最佳的工作狀態,同時排除設備和工藝上的影響量,使鶴管的殘留量為零,確保檢測的重復性最佳,然后進行校準。以0.2級容積式流量計為主要計量器具的付油計量裝置進行不確定度評定。在流量為100m3/h下進行校準,測量三次。
1 建立數學模型,列出不確定度傳播律
1.1 數學模型
6 不確定度的報告
被校準的付油計量裝置在流量為100m3/h時的示值誤差為0.24%,測量結果的相對擴展不確定度為[U=0.14%][(k=2)]。
7 結語
本文針對標準裝置校準容積法付油計量裝置的不確定度進行了分析評定,給出了測量結果的相對擴展不確定度,明確了測量結果的不確定度范圍,為有效評價容積法付油計量裝置的校準結果提供了方法,為提升和控制付油計量裝置的精度提供了技術支撐。
【參考文獻】
[1] 通用計量術語及定義:JJF 1001-2011[S].
[2] 測量不確定度評定與表示:JJF 1059.1-2012[S].
[3] 倪育才.實用測量不確定度[M].北京:中國質檢出版社 2016.
[4] 液體容積式流量計:JJG 667-2010[S].
[5] 付油計量裝置:JJG(遼) 58-2011[S].