摘 要:針對架空輸電線路用防振錘滑移進行原因分析,發現線夾結構不合理是問題產生的主要原因。該文提出將防振錘線夾線槽設計成多紋加涂層型,以增大線夾與導線之間的摩擦力,經試驗,結構改進設計提高防振錘的滑移荷載。
關鍵詞:輸電線路;防振錘線夾;滑移;結構;設計
中圖分類號:TH122 文獻標志碼:A 文章編號:2095-2945(2024)30-0132-04
Abstract: The cause of the slip of the anti-vibration hammer used in overhead transmission lines was analyzed, and it was found that the unreasonable structure of the cable clamp was the main cause of the problem. In this paper, it is proposed to design the wire groove of the anti-vibration hammer clip into a multi-pattern and coated type to increase the friction between the wire clip and the wire. After testing, the structural improvement design increases the sliding load of the anti-vibration hammer.
Keywords: transmission line; anti-vibration clamp; slip; structure; design
架空輸電線路的導、地線在受到穩定且不大的微風(風速0.5~6 m/s)作用時,導線背風面將產生以一定頻率上下交替變化的氣流旋渦,該氣流旋渦使架空線受到上下交變的脈沖力作用。當氣流旋渦的交替變化頻率與架空線固有自振頻率相等時,在垂直平面內產生共振[1]。導線振動時,導線懸掛處的工作條件最為不利,長時間和周期性的振動將造成導線疲勞損壞,使導線發生斷股、斷線[2]。
為了預防或減輕導、地線的振動,常用的方法是在懸掛導、地線線夾的附近安裝一定數量的防振錘[3]。當導、地線發生振動時,防振錘能有效減少導、地線的振動。然而現有部分工程防振錘,安裝運行一段時間后仍出現滑移現象,會對線路安全運行造成一定的隱患。本文分析防振錘的滑移現象,并從振動的起因及防振錘產品結構進行分析,并提出結構改進方案。
1 微風振動的成因、危害及防控措施
1.1 微風振動
微風振動是指外形近似于圓柱的架空輸電線路中的導、地線,懸掛在離地有一定高度的半空中,因氣候環境的影響受到具有一定力度的風……