Zhi-Hui Duan, Sheng-Yun Zhou
Abstract BACKGROUND To avoid acute variceal bleeding in cirrhosis, current guidelines recommend screening for high-risk esophageal varices (EVs) by determining variceal size and identifying red wale markings. However, visual measurements of EV during routine endoscopy are often inaccurate.AIM To determine whether biopsy forceps (BF) could be used as a reference to improve the accuracy of binary classification of variceal size.METHODS An in vitro self-made EV model with sizes ranging from 2 to 12 mm in diameter was constructed. An online image-based survey comprising 11 endoscopic images of simulated EV without BF and 11 endoscopic images of EV with BF was assembled and sent to 84 endoscopists. The endoscopists were blinded to the actual EV size and evaluated the 22 images in random order.RESULTS The respondents included 48 academic and four private endoscopists. The accuracy of EV size estimation was low in both the visual (13.81%) and BF-based (20.28%) groups. The use of open forceps improved the ability of the endoscopists to correctly classify the varices by size (small ≤ 5 mm, large > 5 mm) from 71.85% to 82.17% (P < 0.001).CONCLUSION BF may improve the accuracy of EV size assessment, and its use in clinical practice should be investigated.
Key Words: Accuracy; Liver cirrhosis; Esophageal varices; Endoscopy; Measurement
Accurate size estimation of esophageal varices (EVs) is essential for determining the exact diagnostic category, appropriate therapy, and observational intervals for patients with liver cirrhosis[1-3]. Visual estimation is currently the most commonly used method, but the estimation of EV size during endoscopy is highly inconsistent among different endoscopists[4-6], with only fair to moderate interobserver agreements reflected by kappa values of 0.38–0.59. In clinical practice, a cut-off diameter of 5 mm is used to classify varices as large or small. However, misclassification of variceal size may occur due to the lack of a reference during endoscopy and variable degrees of air insufflation[7]. As inaccurate assessment of variceal size may negatively influence the management of liver cirrhosis, the development of a method for accurate variceal size measurement has received much attention in recent years. Although the use of biopsy forceps (BF) has been advocated as a reference to improve the accuracy of variceal size classification, there are currently no reported validity data. We therefore aimed to investigate whether the use of BF improves the accuracy of variceal size estimation. Since accurate measurement of exact EV diameter is difficult in clinical practice, we constructed anin vitroEV model with a known variceal size as the gold standard for this simulation study.
Anin vitroesophagus model was constructed and modified by affixing 22 silicone varices (Figures 1 and 2). A common type of BF (Model 220824, Hangzhou Kangsheng Medical Equipment Corporation, Hangzhou, China) was used. The maximum opening distance between the two cups of the BF was approximately 6 mm. The exact EV size was determined by manually measuring the varices using calipers and calculating the average of three measurements using the roundingoff method. An Olympus GIF H260 gastroscope (Olympus, Tokyo, Japan) was used. The simulated EV with known exact variceal size was then used to evaluate the potential of BF for improving the accuracy of EV size estimation. An imagebased online test was compiled and completed by 52 endoscopists to compare the accuracy of conventional visual estimation with estimations using BF as a reference point.
An experienced endoscopist (Duan ZH) performed all the gastroscopic procedures and high-definition endoscopic images were saved. Eleven varices with known sizes, ranging from 2 to 12 mm in diameter, were photographed using a gastroscope without BF as a reference. The varices were subsequently photographed using BF as a reference during endoscopy. The BF were viewed at approximately the same length and location in all the images (Figure 2).

Figure 1 Flow chart of this study. EV: Esophageal varices.

Figure 2 Examples of images for online testing in this study. A: The actual size of the varices in picture (traditional visual method) was 3 mm; B: The actual size of the varices in the picture (biopsy forceps as a reference) was 3 mm; C: The actual size of the varices in the picture (visual method) was 7 mm; D: The actual size of the varices in the picture (biopsy forceps method) was 7 mm.
A total of 84 endoscopists were invited to participate in this study by Wechat, as per Wenjuanxing, an online survey platform. Inclusion criteria for the endoscopists included voluntary participation in an anonymous, online image-based test and submission after completing all answers. Each endoscopist completed a questionnaire that included 30 questions on age, sex, professional experience, type of practice setting, and number of gastroscopies performed per year. All the participants were blinded to the actual sizes of the simulated varices and were asked to assess the largest diameter of each of the 11 artificial varices, first without BF and then with BF as a reference. For each EV, the participants had to choose the size as a whole number ranging from 2 to 15 mm. The images were shown to the participants in random order and participants could not go back to revise previous answers.
The study was approved by the Institutional Review Board of Xingtai People’s Hospital on June 28, 2023 (approval No. 2023046). Patient consent was not required as no patient data were collected. Each participant volunteered for the study and provided informed consent for participation in this anonymous online survey.
To date, the accuracy of open BF-based estimation of EV size compared with visual estimation has not been reported. A minimum of 499 measurements were needed in both the visual estimation and open BF-based estimation groups for an independent test with a power of 80%,α= 0.05. This study included 572 measurement datapoints for each of the two groups.
The measurement error was calculated by subtracting the gold standard from the corresponding estimation result. Continuous variables were expressed as mean ± SD, and categorical variables were expressed as frequencies and percentages. Student’sttest was used to compare differences in measurement error of the two estimation methods. The overall accuracy of classifying variceal size categories was compared using the χ2test. Statistical significance was set atP< 0.05 (two-tailed). G*Power for Windows version 3.1.9.7 was used to calculate the sample size. SPSS version 25.0 (IBM Corp., Armonk, NY, USA) was used for statistical analysis.
Fifty-two endoscopists, including 48 academic and four private endoscopists, responded and completed the online survey. The average gastroscopic experience was 11.0 ± 6.9 years, and 37 participants performed > 500 gastroscopies yearly (Table 1). The endoscopists first performed a visual evaluation of 11 images of simulated varices with known exact sizes, then they evaluated the images using BF as a reference. A total of 1144 measurements were collected (572 in the visual group and 572 in the open BF group).

Table 1 Demographic characteristics of participants
The exact measurement accuracies using the visual and open BF-based estimation methods were 13.81% and 20.28%, respectively (P=0.004) (Table 2). The use of open BF significantly improved the accuracy of correctly classifying large varices (> 5 mm), but did not improve the accuracy of classifying small varices (≤ 5 mm) (Table 2). Table 3 shows the number of exact classifications of simulated EV with actual diameters ranging from 2 mm to 12 mm by visual or open BFbased estimation.

Table 2 Measurement accuracy of 52 endoscopists for each measurement condition

Table 3 Comparison of actual versus estimated varices size using a visual estimation method and open biopsy forceps method
When the varices were classified as small (≤ 5 mm) or large (> 5mm), the use of open BF improved the accuracy of the estimated sizes (percentage of measurements where the varices were classified correctly into the correct size category) (P< 0.001) (Table 3). When data from participants with less experience (< 500 gastroscopies per year,n= 15) were analyzed separately, the use of BF improved the overall accuracy of categorizing the size from 75.15% to 85.45%(P=0.019).The greatest improvement was observed for large varices, with the classification accuracy of all 52 endoscopists improving from 64.56% to 78.85% (P< 0.001) (Tables 2 and 3).
Upper gastrointestinal bleeding due to EVs in patients with portal hypertension is associated with high morbidity and mortality rates[1]. As the risk of variceal bleeding is assessed by variceal size[1], accurate measurement of EV size is important. We therefore aimed to improve the accuracy of endoscopists to estimate EV size. Comparison of the accuracy of open BF-based estimation with visual estimation of EV size in a simulated esophagus model revealed that the ability of endoscopists to correctly classify varices by size (smallvslarge) is significantly improved by the use of open BF. A previous study by Liet al[8] evaluated the efficacy of an endoscopic diameter rulerin vitro; however, handling of the endoscopic ruler was complex and increased the cost. A study by Jinet al[9] reported that a virtual ruler based on artificial intelligence was more accurate in measuring variceal diameter in clinical practice; however, the sample size of the study was small (n= 7), and the gold standard for variceal diameter was unknown. Notably, both the virtual and endoscopic rulers[8,9] require placement of external devices that are not used in routine endoscopic practice. In contrast, BF are used in routine endoscopic procedures, and two studies[10,11] have confirmed that BF-based estimation is more accurate than visual estimation, which is consistent with our results.
Although previous studies show that endoscopists often estimate the size of esophageal lesions inaccurately when using conventional endoscopy, with an overall incorrect estimation rate of 67.9%[12], there are few studies on the accuracy of EV size determination that report the actual EV size[8]. Anin vitrostudy by Liet al[8] used columnar objects that mimicked varices, but their shapes were dissimilar to those of the human esophagus and varices. In contrast, our silicone EV model exhibited greater similarity to these structures.
This study had some limitations. First, it was limited by the use of a simulation model, which was required as measuring the actual sizes of EV in clinical practice is difficult. To validate BF measurements in humans in follow-up studies, we will select physicians who demonstrated a high accuracy in variceal size measurement when participating in this study. Second, the shape of the varices in our model differed from the shape of human varices. However, as our preclinical study focused primarily on the maximum diameter of the veins, it is reasonable to assume that the use of BF may be feasible in future studies in humans.
This study had several strengths. First, we introduced a self-made, simple, low-cost, artificial EV model with specified variceal sizes. Second, we used still images with similar viewing distances and angles when taking photographs during endoscopy to strictly control the experimental conditions, such as image distortion from the eye lens of the gastroscope[13]. Third, the sample size was large, including 52 participants and 1144 measurements; this exceeded the sample size of a previous study (680 measurements)[14], and thus represented the largest study to date to evaluate endoscopic and BFbased estimation of variceal size.
The use of open BF can significantly improve EV binary classification accuracy. Additional clinical studies using BF during gastroscopy are needed to validate our results.
Accurate estimation of esophageal varices (EVs) is essential because variceal diameter is used to determine the exact diagnostic category, appropriate therapy, and observational intervals for patients with liver cirrhosis. However, visual estimation of EV size by endoscopists are often inaccurate.
Upper gastrointestinal bleeding due to EVs is associated with high morbidity and mortality rates. As the risk of variceal bleeding is assessed by variceal size, accurate measurement of EV size is important. We therefore need to improve the accuracy of endoscopists to estimate EV size.
We aimed to evaluate whether open biopsy forceps (BF) can be used to improve the accuracy of binary classification of EV size.
A simulated EV model with known EV sizes was constructed. An online image-based test comprising 11 endoscopic images of simulated EV without BF and 11 endoscopic images of EV with BF was evaluated in random order by 52 endoscopists.
The ability of endoscopists to correctly classify the varices according to size (small, ≤ 5 mmvslarge, > 5 mm) was improved from 71.85% to 82.17% with the use of open BF (P< 0.001).
This study showed that using open BF as a reference may improve the assessment of variceal size. However, its use in clinical endoscopy practice requires further investigation.
Using open BF as a reference may significantly improve the accuracy of esophageal variceal size binary classification. Additional clinical studies using BF during gastroscopy are required to confirm our findings.
Author contributions:Duan ZH contributed to the concept and design of this study, acquisition, analysis, interpretation of data, statistical analysis and drafting of the manuscript; Duan ZH and Zhou SY were involved in the critical revision of the manuscript for important intellectual content.
Institutional review board statement:This study was approved by the ethics committee of Xingtai People’s Hospital on June 28,2023 (approval No. 2023046), and in accordance with the Helsinki Declaration of 1975.
Informed consent statement:All study participants provided informed consent prior to this online survey.
Conflict-of-interest statement:All the authors report no relevant conflicts of interest for this article.
Data sharing statement:The original data can be obtained from the correspondence author.
STROBE statement:The authors have read the STROBE Statement-checklist of items, and the manuscript was prepared and revised according to the STROBE Statement-checklist of items.
Open-Access:This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/
Country/Territory of origin:China
ORCID number:Zhi-Hui Duan 0000-0001-9571-2032; Sheng-Yun Zhou 0000-0001-6865-6709.
S-Editor:Wang JJ
L-Editor:Kerr C
P-Editor:Zhao YQ
World Journal of Gastrointestinal Surgery2024年2期