Influence of soil resistivity on stray current in power supply system of urban rail transit

2022-09-19 06:50:30CHENWanglongLIYaningWANGYe

CHEN Wanglong, LI Yaning, WANG Ye

(1. School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China;2. School of Environmental and Municipal Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China)

Abstract: In order to explore the influence of soil resistivity on stray current in power supply system of urban rail transit, we establish an equivalent circuit model of the rail-to-ground structure based on resistance network method first. After measuring the soil resistivity of a real subway system, a simulation model is established in Matlab to obtain the stray currents at different soil resistivities. Then the influence of soil resistivity on stray current is analyzed. Afterwards, to verify the rationality and reliability of the simulation model, we design a test circuit to measure the stray current and rail-to-ground voltage in a real subway system, and a comparison of the experimentally measured results and simulation results is presented. The results show that the stray current is the maximum when the soil resistivity is 211.57 Ω·m; when the soil resistivity is 768.47 Ω·m, the stray current is the minimum, that is, the smaller the soil resistivity, the greater the stray current. Therefore, the resistivity should be increased as much as possible when ramming the track foundation in urban rail transit system.

Key words: urban rail transit; power supply system; stray current; soil resistivity; four-electrode method

0 Introduction

The urban rail transit features fast speed, punctuality, large carrying capacity and low energy consumption so that it plays an increasingly important role in people’s daily lives. Accordingly, there exist currents leaking from the railway tracks into the ground, which is called stray currents caused by various elements[1-3]. At present, the research on stray currents mainly focuses on optimization of circuit model of rail-to-ground structure[4], design of current drainage net[5-8], electrochemic corrosion mechanism of metal pipelines[9], dynamic characteristics of stray current[10], layout of traction power supply structure[11-12], selection of grounding modes of traction substation[13], magnitude of resistivity[14]and voltage level of traction substation[15], etc. However, most of them focus on simulation analysis but lack of experimental data. Moreover, the theoretical analysis and experimental test on soil properties is uncomprehensive although soil resistivity is an important factor which affects the spatial and temporal distribution of stray current but is rarely reported. In our work, the influence of soil resistivity on stray current is studied by simulation and experimental tests on the soil of a real subway system.

1 Equivalent circuit of rail-to-ground structure

Taking a real subway system as the research object, considering the existence of stray current, we establish the equivalent circuit model of rail-to-ground structure with the distribution of stray current, as shown in Fig.1.

Fig.1 Equivalent circuit diagram of rail-to-ground structure of a subway system

The traction substation is regarded as the current source(I), each metal structure of the rail is regarded as a resistor(R), and the rail is regarded as being composed of series resistors. The transition resistance between the rail and the ground is represented asRg, and soil resistance is represented asRt. Based on this, letα2=R/Rg, we can derive the changing laws of stray current and rail-to-ground voltage as[17-19]

(1)

(2)

wherexis the distance from any point on the rail to the substation;Lis the distance between the locomotive and traction power substation;u(x) is the voltage at positionx; andis(x) is the stray current at positionx.

2 Measurement of soil resistivity

Soil resistivity is defined as the average value of soil resistance per unit length. It directly affects the grounding resistance of grounding device as well as the voltage distribution of ground network. Fig.2 shows the schematic diagram to measure the soil resistivity by means of four-electrode method.

Fig.2 Schematic diagram of measuring soil resistivity by four-electrode method

Soil resistivity can be got by

(3)

Table 1 Measurement results of soil resistivity

3 Simulation of stray current and rail-to-ground voltage

3.1 Simulation of stray current

According to the equivalent circuit model of the rail-to-ground structure in section 1, we can establish the simulation model of stray currents based on Matlab, as shown in Fig.3.

Fig.3 Simulation model of stray current and rail-to-ground voltage distribution

Fig.4 Simulation results of stray currents

The stray current distribution within a given rail section is shown in Fig.5.

Fig.5 Stray current distribution within a given rail section

It can be seen that in the direction parallel to the rail, the stray current increases first and then decreases, and its maximum value occurs in the middle of the rail section; in the direction perpendicular to the rail, the stray current decreases from the rail to both ends.

3.2 Simulation of rail-to-ground voltage

Fig.6 Simulation results of rail-to-ground voltage

The rail-to-ground voltage distribution within a given rail section is shown in Fig.7. It can be seen that in the direction parallel to the rail, the rail-to-ground voltage reaches the maximum at the track terminal and then linearly decreases to the minimum in the middle of the the track section; in the direction perpendicular to the rail, the rail-to-ground voltage decreases from the rail to both ends.

Fig.7 Rail-to-ground voltage distribution within a given rail section

4 Experimental verification

To verify the rationality and reliability of the simulation model, we design a test circuit[16]to measure the stray current and rail-to-ground voltage in a real subway system, as shown in Fig.8. A Fistech FT10010 DC power supply (output voltage: 0-100 V, output current: 0-10 A) is used to simulate the traction substation, and 11 cement resistors in series (R=1 Ω,P=10 W) are used to simulate the rails. Ten 7-cm probes are inserted into the soil at an interval of 4 cm between probes, and every probe is welded to the corresponding nodes between the two rail resistors. The negative pole of VICTOR 98A+ voltmeter is connected to the soil and its positive pole is connected to the nodes. In this way, the voltage between the node and the soil can be measured. The measured traction current values are displayed on ammeter A1, the measured stray current values are displayed on ammeter A2, and the measured rail-to-ground voltage values are displayed on voltmeter V. In our study, when the traction current is 0.5 A, 1.0 A, 1.5 A and 2 A, respectively, the average values of stray currents and rail-to-ground voltage are obtained through three times’ measurement.

Fig.8 Measuring principle diagram of stray current and rail-to-ground voltage

The simulation results and experimental results of stray currents and rail-to-ground voltages at different soil resistivities are compared and analyzed, as shown in Figs.9-10.

It can be seen from Fig.9 that with the increase of the traction current, the stray current flowing into the ground increases. If the the traction current is fixed, with the increase of soil resistivity, the stray current decreases. The maximum error between the simulation results and the measured results is about 1.5%, which is caused probably by the thermal effect of resistance, the error between the Matlab simulation calculation model and the experimental measurement.

Fig.9 Comparison of experimental and simulation results of stray current

It can be seen from Fig.10 that with the increase of the traction current, the amplitude of rail-to-ground voltage reaches the maximum at both ends of the track section and the minimum in the middle of the track section. The maximum error between the simulation results and the measured results is about 5%.

Fig.10 Comparison of simulation and experimental results of rail-to-ground voltage

5 Conclusions

Through the simulation analysis and experimental verification of stray current and rail-to-ground voltage at different soil resistivities, the conclusions are as follows:

2) With the increase ofthe traction current, the amplitude of rail-to-ground voltage reaches the maximum at both ends of traction section and reaches the minimum in the middle of traction section.

3) The error between the simulation results and the experimental results of the stray current is about 1.5%, and error of the rail-to-ground voltage is about 5%.


登錄APP查看全文

主站蜘蛛池模板: 99久久精品国产精品亚洲| 国产成人亚洲精品蜜芽影院| 天堂中文在线资源| 中文字幕人妻av一区二区| 日韩区欧美区| 日韩一二三区视频精品| 精品国产欧美精品v| 亚洲va视频| 国产情精品嫩草影院88av| 永久成人无码激情视频免费| 特级毛片免费视频| 自偷自拍三级全三级视频| 亚洲精品片911| 国产SUV精品一区二区6| 亚洲日韩第九十九页| 日韩在线观看网站| 久久99热这里只有精品免费看| 亚洲a级毛片| 欧美a级在线| 风韵丰满熟妇啪啪区老熟熟女| 亚洲精品制服丝袜二区| 丝袜高跟美脚国产1区| 婷婷激情亚洲| 亚洲综合婷婷激情| 国产精品人莉莉成在线播放| 毛片免费试看| 一级成人a做片免费| 午夜精品久久久久久久99热下载 | 成人a免费α片在线视频网站| 欧美色图久久| 免费va国产在线观看| 国产无人区一区二区三区| aaa国产一级毛片| 日韩毛片免费观看| 精品第一国产综合精品Aⅴ| Jizz国产色系免费| 18禁黄无遮挡免费动漫网站| 国产精品污污在线观看网站| 亚洲精品不卡午夜精品| 欧美精品v| 亚洲精品无码高潮喷水A| 综合色88| 精品在线免费播放| 人妻精品久久无码区| 在线精品自拍| 在线观看国产精美视频| 综1合AV在线播放| 2020亚洲精品无码| 19国产精品麻豆免费观看| 国产无码在线调教| 久久精品无码中文字幕| 日本手机在线视频| 中文字幕永久视频| 欧美97色| 国产麻豆aⅴ精品无码| 无码精油按摩潮喷在线播放| 婷婷六月综合网| 亚洲欧美h| 亚洲人成网址| 在线视频亚洲色图| 国产成人综合欧美精品久久| 精品一区国产精品| 国产成人夜色91| 中文字幕亚洲第一| 日韩精品亚洲一区中文字幕| 18禁高潮出水呻吟娇喘蜜芽| 亚洲成人免费看| 97影院午夜在线观看视频| 69视频国产| 亚洲人成电影在线播放| 免费中文字幕一级毛片| 成人在线第一页| 97精品久久久大香线焦| 亚洲最黄视频| 97se亚洲综合| 在线色国产| 国产人成网线在线播放va| 91精品国产无线乱码在线| 中文字幕 欧美日韩| 58av国产精品| 亚亚洲乱码一二三四区| 亚洲av无码专区久久蜜芽|