李新昌 王昱









摘 要:建筑給水方式有多種,其給水系統設計需要確定多個參數。管道設計流量、水泵設計流量和水箱容積是重要設計參數,也是難點所在。對常見建筑給水方式的工況進行分析,解讀建筑給水排水設計標準相關規定,確定這些參數設計計算方法,為給水系統設計提供參考。
關鍵詞:建筑給水;低位儲水池容積;高位水箱容積;水泵流量
中圖分類號:TU821 文獻標識碼:A 文章編號:1003-5168(2021)25-0083-04
Analysis on Design Difficulties of Different Water Supply Modes in Buildings
LI Xinchang WANG Yu
(1.Baoji Municipal Engineering Maintenance Service Center, Baoji Shaanxi 721000;2.Baoji Tongji Water Co., Ltd., Baoji Shaanxi 721000)
Abstract: There are many modes of building water supply,many parameters need to be determined in the design of each water supply system. pipeline design flow、design flow of water pump and water tank volume are important design parameters,It is also the difficulty.The working conditions of each building water supply system are analyzed,and regulations in standard for design of building water supply and drainage are interpreted,then the design and calculation methods of those parameters are determined. This provides a reference for water supply system design.
Keywords: building water supply;low level reservoir volume;volume of high-level water tank;flow of water pump
1 建筑給水設計要點
給水系統設計時要確定眾多參數,其中水泵和管道流量、儲水池(箱)容積是給水系統設計計算的核心問題,也是難點問題。因此,本文重點討論給水系統管道、水泵流量和儲水池(箱)容積問題。給水系統儲水池通常分為低位儲水池(箱)、中間水箱、高位水箱等。
建筑每種給水方式有其特點和適用性,不同的建筑應選擇合理的給水方式。設計時應遵循《建筑給水排水設計標準》(GB 50015—2019)[1]的規定進行。但是,很多工程師設計時只根據經驗進行設計,不進行理論計算。即使進行了計算,往往也存在很多問題。因此,有必要對建筑給水的設計計算問題進行分析和梳理,以便設計結果能夠符合標準規定。許多學者[2-4]都已經對此進行了分析,但是還不夠全面。本文比較全面地分析建筑給水系統的設計,對這幾個難點問題的設計進行分析。
2 各種給水方式設計計算分析
2.1 引入管-建筑直接供水方式
支管管段流量根據《建筑給水排水設計標準》(GB 50015—2019),結合建筑性質,選擇設計秒流量計算公式計算?!?br>