999精品在线视频,手机成人午夜在线视频,久久不卡国产精品无码,中日无码在线观看,成人av手机在线观看,日韩精品亚洲一区中文字幕,亚洲av无码人妻,四虎国产在线观看 ?

Treatment of Stanford type A aortic dissection with triple prefenestration,reduced diameter, and three-dimensional-printing techniques: A case report

2021-02-22 06:20:06MingZhangYuanHaoTongChenLiuXiaoQiangLiChangJianLiuZhaoLiu
World Journal of Clinical Cases 2021年1期

Ming Zhang, Yuan-Hao Tong, Chen Liu, Xiao-Qiang Li, Chang-Jian Liu, Zhao Liu

Ming Zhang, Yuan-Hao Tong, Chen Liu, Xiao-Qiang Li, Chang-Jian Liu, Vascular Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, Jiangsu Province, China

Zhao Liu, Vascular Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 21008, Jiangsu Province, China

Abstract BACKGROUND A 63-year-old female was diagnosed with acute Stanford type A aortic dissection.The patient had pain in the chest and back for 1 wk. The computed tomography angiography (CTA) showed Stanford type A aortic dissection (Myla type III aortic arch). The intimal tear was located at the top of the aortic arch and retrograded to the ascending aorta.CASE SUMMARY Preoperatively, a three-dimensional (3D)-printed model of the aortic arch was made according to CTA data. Then, under the guidance of the 3D-printed aortic model, a pre-fenestrated stent-graft was customized, and the diameter of the stent-graft was reduced intraoperatively by surgeons. 3D printing, triple prefenestration, and reduced diameter techniques were used during the surgery. The CTA examinations were performed at the 3rd mo and 1st year after the surgery; the results showed that the aortic dissection was repaired without endoleak, and all three branches of the aortic arch remained unobstructed.CONCLUSION Applying the triple pre-fenestration technique for aortic arch lesions was feasible and minimally invasive in our case. The technique provides a new avenue for thoracic endovascular aortic repair of Stanford type A aortic dissection.

Key Words: Type A aortic dissection; Aortic arch; Pre-fenestration; 3D printing;Endovascular repair; Case report

INTRODUCTION

Stanford type A aortic dissection (TAAD) is an extremely dangerous disease in which the dissection involves the aortic arch or ascending aorta. Traditional thoracotomy surgery is traumatic and has many postoperative complications[1]. Performing endovascular repair in the aortic arch also has high rates of mortality and complications, so the ascending aorta is perhaps the last frontier in thoracic endovascular aortic repair (TEVAR)[2]. Currently, thein situfenestration technique is widely used in TAAD, but it requires the establishment of temporary bypass, which can increase the risk of cerebral infarction[3]. Customized pre-fenestrated stent-grafts can adapt to the anatomical variation in the aortic arch. We reported a case of TAAD that was successfully treated by triple pre-fenestration, reduced diameter, and threedimensional (3D)-printing techniques.

CASE PRESENTATION

Chief complaints

Sudden chest pain that lasted for 1 wk.

History of present illness

A 63-year-old female patient was admitted to the Department of Vascular Surgery of our hospital due to sudden chest pain in October 2018.

History of past illness

The patient had a history of coronary heart disease and underwent coronary stent implantation in May 2017. She had hypertension for more than 10 years and was treated regularly with nifedipine.

Personal and family history

The patient’s parents were healthy, and her personal history was normal.

Physical examination

Upon admission, the patient's body temperature was 36.5 °C, pulse was 72 times/min,and blood pressure was 130/74 mm/Hg. Her breathing was steady, averaging 14 breaths per min. The patient had no chest deformities, and the breath sounds in both lungs were normal. There was no abnormal uplift in her precardiac region and no obvious expansion of her cardiac dullness boundary. Her heart rate was regular at 72 beats/min, and there was no pathological murmur. There were no positive signs in the abdomen and no swelling in the lower limbs.

Laboratory examinations

There were no significant abnormalities in preoperative routine blood tests, routine stool tests, or biochemical examinations. The occult blood test of urine analysis showed weak positive results. The value of D-dimer was 1.87 mg/L in plasma.

Imaging examinations

The computed tomography angiography (CTA) scan showed Stanford type A aortic dissection (Myla type III aortic arch). The intimal tear was located at the top of the aortic arch and retrograded to the ascending aorta (Figure 1). A series of operations and imaging examinations were performed to address the intractable situation(Table 1).

FINAL DIAGNOSIS

Stanford type A aortic dissection, coronary heart disease (postoperative coronary stent implantation), and hypertension.

TREATMENT

Stage 1

Preoperatively, a 3D-printed model of the aortic arch was made according to CTA data. The original computed tomography scan data were input into Mimics software(Materialise’s interactive medical image control system; Materialise Co., Leuven,Belgium) for 3D reconstruction. The 3D reconstruction data were input into design software (Geomagic Studio 2014; Geomagic Co., Morrisville, NC, United States) for further pre-processing. The computer-aided design for the mathematical model of arteries could be obtained by using a reverse engineering technique to reconstruct the nonparametric surface of arteries. To simulate the situation after stent implantation,we dilated the narrow true lumen of the aortic dissection. Geomagic Design Direct 2014 (Geomagic Co.) was used to locate the positions of the three branches of the aortic arch. Then, we used it to design the 3D printing guide plate and print the model.Finally, the 3D-printed model was disinfected with ethylene oxide (Figure 1).

Stage 2

After successful anesthesia, the guidewire and gold-standard catheter were inserted through the right femoral artery, entering the ascending aorta. Angiography was performed to evaluate the dissection conditions. This was consistent with the computed tomography scan results and indicated that the dissection was located at the aortic arch and involved the ascending aorta.

A covered aortic stent-graft (40 mm × 200 mm; Captivia, Medtronic Co., Fridley,MN, United States) was released in a 3D printing model to determine the prefenestrated positions. We used an electric pen (CIRX Co., China) to make the prefenestration (10 mm for the innominate artery, 7 mm for the left carotid artery, and 5 mm for the left subclavian artery). A dehaired platinum spring coil (Cook Co.,Bloomington, IN, United States) was sewn up to the edge of the fenestration and the large curved side of the aortic arch with 5-0 nonabsorbent sutures (JNJ Co., New Brunswick, NJ, United States) to serve as a marker during the operation. Additionally,4-0 nonabsorbent sutures (JNJ Co.) and V18 guidewires (Boston Scientific Co.,Marlborough, MA, United States) were used to reduce the diameter of the stent to 24 mm (Figure 1).

Subsequently, we returned the modified stent-graft to the conveying sheath.Bilateral cervical and left elbow incisions were made, and the vascular sheaths were inserted into the bilateral carotid arteries and the left brachial artery. A soft guidewire with a catheter was passed from the right femoral artery to the descending aorta and then was exchanged with a stiff guidewire. A covered stent-graft (32 mm × 80 mm;Ankura, Life Tech Co., China) was released at the descending aorta as a distal restrictive stent. The modified stent-graft was released in the aortic arch. The directions of the marks and fenestrations were adjusted to the large curved side of the aortic arch. The stent-graft was released, and the diameter of the stent-graft was reduced. The guidewires were super-selectively sent through the fenestrations into the modified stent-graft. A covered stent-graft (13 mm × 40 mm; Fluency, Bard Co.,Tempe, AZ, United States) was released through the guidewire in the innominateartery. A covered stent-graft (10 mm × 40 mm; Fluency, Bard Co.) was released through the guidewire in the left carotid artery. Another 10 mm × 40 mm covered stent-graft (Fluency, Bard Co.) was released through the guidewire in the left subclavian artery. After confirming the correct position by angiography, we recovered the original diameter of the modified stent-graft. The expanding balloons were used to expand the fenestrations. Angiography showed that all the stents were in the correct positions without obvious endoleak, and the three branches of the aortic arch were unobstructed. The operation lasted approximately 4.5 h: 1.5 h for stent-graft modification and 3 h for the operation (Figure 2). The radiation time was approximately 38 min, and the total radiation dose was 1029 mGy. Intraoperative blood loss was approximately 200 mL without transfusion.

Table 1 Timeline

Figure 1 Details of treatment. A and B: Preoperative computed tomography reconstruction and cross-sectional image; C and D: Design of the threedimensional-printed model; E and F: Determination of the fenestrations and reduction in the diameter of the stent.

The patient recovered well after the surgery and returned to the general ward.There was no temporary bypass during the operation, and no neurological complications occurred after the surgery. The patient received long-term antiplatelet treatment with aspirin (100 mg/d) and clopidogrel (50 mg/d) to prevent in-stent restenosis, and she was discharged from the hospital 10 d after the surgery.

OUTCOME AND FOLLOW-UP

Figure 2 Postoperative follow-up. A: Preoperative angiography; B: Three branched stents entering the aortic stent; C: Postoperative angiography of the aortic arch; D-F: Computed tomography reconstruction and cross-sectional image at 3 mo after surgery; G and I: Computed tomography reconstruction and cross-sectional image at 1 year after surgery.

The CTA examination performed 3 mo after the surgery showed that the stents were in the correct position without displacement, and all three branches of the aortic arch were unobstructed. An intramural hematoma had formed. However, there was a small endoleak outside of the aortic stent-graft (Figure 2). Fortunately, the 1styear follow-up CTA examination after surgery indicated that the endoleak had completely disappeared. The intramural hematoma was mostly absorbed, and the lumen of the primary aortic dissection aneurysm had not enlarged further (Figure 2).

DISCUSSION

In recent years, TEVAR has achieved rapid development and has been widely applied to various descending aortic diseases. Compared with traditional open surgery,TEVAR is safer and leads to fewer perioperative complications[4]. Because of the anatomical complexity of the aortic arch, there are still many difficulties to be solved when we apply TEVAR to treat TAAD[5]. At present, the most common TEVAR techniques include the chimney technique, branched stent technique, andin situfenestration and pre-fenestration techniques. The chimney technique is simple, but postoperative endoleak and mid- to long-term retrograde ascending aortic dissection are common[6]. The branched stent technique is less likely to cause endoleak because there is no gap between the stents. However, because only single-branched stents are available, hybrid surgery is still needed for three-branch lesions[7]. Thein situfenestration technique can reconstruct anatomical structure, but it is not applicable to all anatomical conditions. For cases of a Myla typeaortic arch,in situfenestration would be more difficult. Temporary bypass during the surgery is needed because blood flow in the aortic arch is blocked. In addition, the frequent operation of the carotid artery and rupture of the covered stent-graft can cause many neurological complications[8]. The pre-fenestration technique can avoid these disadvantages, but it is very important to locate accurately the positions of the fenestrations. If the positions are imprecise, serious complications or even surgical failure can occur.

In our case, the patient received triple pre-fenestration under the guidance of a 3Dprinted aortic model. We successfully completed triple pre-fenestration without blocking carotid blood flow. No temporary bypass was established during the operation, and no neurological complications were observed postoperatively. Singhet al[9]first used the pre-fenestration technique in the treatment of aortic disease in 1996. The pre-fenestration technique is theoretically suitable for all anatomical conditions, and the mid- and long-term patency rates of this technique are higher than those of other techniques. At present, there is no commercial fenestrated stent-graft in China. Customized fenestrated stents are expensive and require a long customization period, which makes them difficult to use in emergency cases. Therefore, it is an ideal choice to perform pre-fenestration on commercial stent-grafts during operations[10,11].For lesions of the aortic arch, accurate pre-fenestration positioning is highly required.In the past, surgeons could only design fenestrated positions based on computerized tomography results and measured linear distances. If the position was not accurate, it would increase the difficulty and time cost of the operation. Although enlarging the diameter of the fenestration was convenient during the operation, it was also prone to cause endoleak. Therefore, accurate positioning is the most important technique in pre-fenestration, especially in triple pre-fenestration[12].

The 3D printing technique enables surgeons to more intuitively understand the relative spatial relationship between the aortic dissection or aneurysm and branches of the aortic arch. Some hospitals use 3D-printed models in individual cases to guide fenestration[13,14]. However, they only use 3D-printed models to understand spatial relationships. We simulated the process of stent release in the aorta with professional software and designed a 3D-printed model according to simulation results.Afterwards, we released the stent-graft in the 3D-printed model to determine accurately the pre-fenestration positions. Temporarily reducing the diameter of the stent was also vital for the success of the operation. In this case, the diameter of the stent was reduced to 60%. The stent could be easily adjusted because it was smaller than the aorta. This technique improved the safety of the surgery. There was a gap between the aortic arch and the stent so that the blood supply of the aortic arch would not be blocked until the stent was completely released. There was adequate blood supply in the carotid arteries, and no bypass was needed, which could reduce neurological complications.

CONCLUSION

The pre-fenestration technique under the guidance of the 3D-printed aortic model provided a new solution for type A aortic dissection The guidance of 3D printing could accurately locate the fenestration positions. Reducing the diameter improved surgical safety. The patient had no neurological complications or endoleak at the 1 year postoperative follow-up. However, the long-term results of the operation need further research.

主站蜘蛛池模板: 成人第一页| 国产高清国内精品福利| 国产精品免费p区| 极品国产一区二区三区| 性网站在线观看| 精品一区二区三区无码视频无码| 美臀人妻中出中文字幕在线| 欧美a在线| 亚洲天堂区| 很黄的网站在线观看| 国产经典免费播放视频| 欧美午夜网站| 国产午夜一级毛片| 精品福利视频网| 精品第一国产综合精品Aⅴ| 亚洲欧美不卡中文字幕| 精品久久久久成人码免费动漫| 欧美视频在线不卡| 黄色网址免费在线| 亚洲 欧美 日韩综合一区| 亚洲精品日产精品乱码不卡| 欧美日韩北条麻妃一区二区| 亚洲成人高清在线观看| 天天综合网色中文字幕| 99热国产这里只有精品9九 | 午夜福利视频一区| 免费看的一级毛片| 好吊妞欧美视频免费| 天天躁夜夜躁狠狠躁躁88| 欧美日本在线一区二区三区| 久久动漫精品| 国产农村妇女精品一二区| 毛片免费观看视频| 欧美在线导航| 国产SUV精品一区二区| 日本影院一区| 国产成人艳妇AA视频在线| 女人18毛片久久| 中文字幕 91| av尤物免费在线观看| 一区二区理伦视频| 好吊色妇女免费视频免费| 99热这里只有成人精品国产| 中文字幕伦视频| 亚洲中文字幕在线精品一区| 国产区在线观看视频| 国产网友愉拍精品| 亚洲小视频网站| 精品无码国产一区二区三区AV| 精品国产欧美精品v| 国产福利在线观看精品| 亚洲欧美激情小说另类| 亚洲成a人在线观看| 亚洲αv毛片| 无码AV动漫| igao国产精品| 国产精品极品美女自在线网站| 网友自拍视频精品区| 亚洲a级毛片| 亚洲第一区在线| 国产精品亚洲一区二区三区在线观看| 鲁鲁鲁爽爽爽在线视频观看 | 亚洲美女操| 超薄丝袜足j国产在线视频| 国产人免费人成免费视频| 欧美日韩高清| 亚洲国产中文精品va在线播放| 91成人试看福利体验区| 嫩草在线视频| 精品自窥自偷在线看| 亚洲国产中文精品va在线播放 | 国产中文一区a级毛片视频| 中文字幕亚洲精品2页| 亚洲swag精品自拍一区| 久久久91人妻无码精品蜜桃HD| 日韩人妻无码制服丝袜视频| 国产污视频在线观看| 97视频精品全国在线观看 | 国产杨幂丝袜av在线播放| 91精品久久久久久无码人妻| 国产精品久久久久鬼色| 日韩欧美国产精品|