Ultrasound guidance for transforaminal percutaneous endoscopic lumbar discectomy may prevent radiation exposure: A case report

2019-08-19 06:15:18MingBoZhangLongTaoYanShouPengLiYingYingLiPengHuang
World Journal of Clinical Cases 2019年10期

Ming-Bo Zhang, Long-Tao Yan, Shou-Peng Li, Ying-Ying Li, Peng Huang

Abstract BACKGROUND Percutaneous endoscopic lumbar discectomy (PELD) has become a mature and mainstream minimally invasive surgical technique for treating lumbar disc herniation (LDH). Repeated fluoroscopy, with more than 30 shots on average, is inevitable to ensure its accuracy and safety. However, exposure to X-rays may pose a threat to human health. We herein report a case of ultrasound (US)-assisted PELD in two levels of LDH to explore a new possibility that can reduce the radiation dose during puncture and cannulation in PELD.CASE SUMMARY A 38-year-old man with low back pain and left leg pain for more than 7 years came to our clinic, his symptoms had aggravated for 1 month, and he was diagnosed with L3-4 and L4-5 disc herniations. He received US-guided PELD with good results: His straight leg elevation increased from 40 to 90 degrees after PELD, and his visual analog scale (VAS) and Oswestry Disability Index scores both significantly decreased immediately and 6 mo after PELD. With the guidance of US, he received only two shots of fluoroscopy (fluoroscopic time: 4.4 s; radiation dose: 3.98 mGy). To our knowledge, this is the first case of US-guided puncture and cannulation of PELD for LDH at two levels.CONCLUSION US could be used to guide PELD and has the potential to largely reduce radiation than traditional X-ray guidance.Key words: Ultrasound; Endoscopic lumbar discectomy; Lumbar disc herniation;Radiation; Guidance; Case report

INTRODUCTION

Transforaminal percutaneous endoscopic lumbar discectomy (PELD) has become a mature and mainstream minimally invasive surgical technique for treating lumbar disc herniation (LDH)[1-4]. Fluoroscopy, to ensure the accuracy of puncture and cannulation, is inevitable. However, radiation exposure with X-ray guidance of PELD may be of concern because of its deleterious effects for both patients and surgeons.Therefore, an image guiding system without X-ray is needed to perform PELD.Ultrasound (US) is a real-time dynamic imaging facility with no ionizing radiation.We herein report a case of US-assisted PELD on a 38-year-old man with two levels of LDH at the same time. Our successful experience may contribute to the application of US-guided PELD in the future.

CASE PRESENTATION

A 38-year-old man [height: 174 cm; weight: 74.5 kg; body mass index (BMI): 24.6 kg/m2] with low back pain and left leg pain for more than 7 years and aggravated symptoms for 1 mo came to our hospital.

History of present and past illness

His previous history and family history were negative. He had lameness on his left leg.

Physical examination

Physical examination showed tenderness and percussion pain radiation to the left leg from the left part of the L4-S1 vertebral spinous processes. Dermal sensation in his left lateral leg and left foot was decreased. Left straight leg raising and strengthening test had positive results (40 degrees).

Imaging examinations

X-ray showed small curvature of the lumbar spine. Computed tomography (CT) and magnetic resonance imaging (MRI) showed L3-4 and L4-5 disc herniations (left margin type) (Figure 1).

FINAL DIAGNOSIS

The patient was diagnosed with LDH of the L3-4 and L4-5 levels (left margin type).

TREATMENT

The patient needed PELD of both L3-4 and L4-5 levels. Institutional approval for PELD was obtained from the ethics committee of our hospital, and the procedure in this study was performed in accordance with the tenets of the Declaration of Helsinki.

Figure 1 X-ray and computed tomography transverse images of the patient. A and B: X-ray images showing small curvature of the lumbar spine; C: Computed tomography (CT) image suggesting L3-4 disc herniation (black arrow, left margin type); D: CT image suggesting L4-5 disc herniation (black arrow, left margin type).

Written informed consent was obtained from the patient. A portable Mindray M9 US system (Mindray, Shenzhen, China) with a C5-1S convex array transducer (central frequency: 5 MHz) was used in this study. The patient laid in a prone position on a radiolucent table with a pillow under his belly. One US physician with more than 4 years of experience in interventional US performed the US guidance. First, a longitudinal section was used to display the transverse processes, and the lowest transverse process was L5. Second, the probe was rotated by 90 degrees to display the L5 transverse process. The probe was moved upward, and the soft tissue in the intervertebral foramen of L4-5 appeared as a circular hyperechoic zone (HZ), which was located below the facet joint (Figure 2). The auxiliary line on the patient’s back skin was drawn at least 9-13 cm away from the midline. Third, the probe was moved to the next highest level to locate the L3-4 intervertebral disc using the same method.

One spinal surgeon with more than 5 years of experience in PELD performed the puncture and cannulation under the guidance of US (Figure 3). The HZ, which was located below the facet joint, was used as the target, and the needle was inserted from the 12 o’clock position to the 3 o’clock position of the HZ. The tip of the 18-gauge spinal needle first touched the facet joint and then slipped into the intervertebral foramen. G-arm X-ray (Whale, Massachusetts, United States) in the anteroposterior and lateral views was used to confirm that the needle tip arrived at the target point. A special instrument set (transforaminal endoscopic surgical system; joimax?GmbH,102 Karlsruhe, Germany) was applied in the procedure. The guidewire was inserted through the spinal needle, which was removed thereafter. Then, the obturator and reamer were introduced along the guidewire. Finally, the expanders and outer sheath of the endoscope were inserted through the guidewire one after another (Figure 4).

The US-guided puncture lasted 4.5 min (2 min for L3-4 and 2.5 min for L4-5), and the US-guided cannulation lasted 5.5 min (2.5 min for L3-4 and 3 min for L4-5). The positions of the puncture needles and working sheaths were accurate, which was tested by two shots of G-arm fluoroscopy, with a total fluoroscopic time of 4.4 s and a total radiation dose of 3.98 mGy. Partial hypertrophied facetectomy was performed using a 3.0-mm endoscopic lateral bur (drill diameter: 3.0 mm, XISHAN, China)(Figure 5). Then, transforaminal PELD was performed as previously described by Wen et al[5].

OUTCOME AND FOLLOW-UP

Figure 2 Transverse ultrasound image of the lumbar spine. SP: Spinous process; FJ: Facet joint; HZ:Hyperechoic area.

The operation decompression lasted 82 minutes for two levels (Figure 5B-D), and it was completed with no complications. The patient's straight leg elevation increased from 40 to 90 degrees after PELD (Figure 6). Immediately following PELD, the visual analog scale (VAS) score of his low back pain decreased from 6 to 1, his leg pain score decreased from 8 to 1, and his Oswestry Disability Index (ODI) score decreased from 73 to 11. Videos of the patient’s gait immediately after surgery showed a normal and symmetric appearance of the two legs, and the spinal MRI after PELD showed complete decompression of the two levels (Figure 7). The patient was taught a set of waist exercises after the operation to reduce the recurrence of disc herniation after PELD. Follow-up at 6 months after PLED showed that the treatment effect remained the same without recurrence, with the patient showing 90 degrees of straight leg elevation, a VAS of 1 for both low back pain and leg pain, and an ODI of 10. The patient was very satisfied with the treatment, especially with the reduction of radiation.

DISCUSSION

Repeated fluoroscopic scanning is essential for the puncture and cannulation during PELD. Fan et al[6]showed that 34.32±4.78 fluoroscopy shots were needed in conventional PELD. They showed that this number was 33.98 ± 2.69 in another group of patients[7]. Patients with more difficult positioning and more treatment levels may receive larger radiation dose, and the same effect will occur in inexperienced surgeons. Fluoroscopic scanning may increase the incidence of malignant tumors,such as thyroid cancer, skin erythema, leukemia and so on[8]. For pregnant women,exposure to X-ray radiation may increase the risk for fetal malformations or developmental abnormalities. High cumulative effective doses also have been found in patients with Crohn’s disease[9], cystic fibrosis[10], and end-stage kidney disease[11].With the guidance of US, the patient in this study received only two shots of fluoroscopy with a low radiation dose of only 3.98 mGy. Future studies with larger samples are needed to validate this technique as an alternative to fluoroscopy.

US has been reported to display intervertebral disc degeneration[12,13]and focal stenosis[14]. It has been used in the guidance of facet joint injections[15], selective nerve root blocks[16], lumbar transforaminal injections[17]and so on. However, due to occlusion of the lumbar spine, displaying the intervertebral foramen remains challenging. Recently, real-time US-MRI or US-CT fusion image virtual navigation has been demonstrated to be an effective and precise method for guiding PELD[18,19]or locating an intraspinal tumor[20]. However, the navigation process performed during these procedures is complicated and requires a special navigation system, such as electromagnetic tracking system, which is not easily available.

Few studies have focused on US-guided PELD. Wu et al[21]reported an initial study of US-assisted PELD and suggested that US-guided PELD can be successfully performed for patients with a BMI less than 24. In this study, we successfully performed US-guided PELD for disc herniation at two levels in a patient with a BMI of 24.6, which suggests that BMI is not always a problem for US guidance. The US guidance method used in our study is different from that used in the above research.They used the facet joint as target and we used the circular HZ above the transverse process, which is located below the facet joint, as the target. Furthermore, the needle was inserted from the 12 o’clock position to 3 o’clock position of the HZ in our study,and no longitudinal scanning was required in our method. The success of the study proves that, although US cannot penetrate bone, soft tissue or bone markers on US can be used as guides to assist the puncture.

Figure 3 Puncture process of the two spinal needles. A: Ultrasound (US)-guided insertion of the two needles; B: Guidewires were then inserted through the two needles; C: US image of one needle (black arrow indicates the tip of the needle; white arrow indicates the track of the needle); D: Position of the needles in the anteroposterior X-ray image; E: Position of the needles in the lateral X-ray image.

US guidance can not only reduce the radiation dose but also provide real-time dynamic guidance of the needle tip. It can reduce the risk for damage to abdominal and retroperitoneal organs, especially in high level disc herniation. The sheath position can also be monitored during cannulation, advising the surgeon when to be forceful and when to be careful.

Disc herniation of two levels requires double puncture time, longer surgical time,and higher radiation dose administered to the patient. However, with the guidance of US, punctures at two levels can be performed at the same time with only two shots of fluoroscopy (fluoroscopic time of 4.4 s and radiation dose of 3.98 mGy). The operation decompression time in our study lasted only 82 min, which is much more likely to be accepted by patients. The success of this case provides a potential for application of this technology. The inclusive and exclusive criteria are meaningful in the process.The inclusion criteria could be radicular leg pain caused by soft LDH with invalid conservative treatment. The exclusion criteria, except for the inherent contraindications of PELD, may include obese patients or patients with hyperechoic fascia muscularis, muscular atrophy, or calcification, since the high attenuation of US makes the anatomical landmarks surrounding the lumbar vertebrae visually unclear.

CONCLUSION

This study is a useful initial attempt and proves that US can be used in the guidance of the puncture and cannulation of PELD, and can largely reduce the radiation dose.The wide popularization of this technique still needs large samples and controlled study. However, with more orthopedists and US physicians mastering spine US and with the additional development of more practical tools, such as punctured guiding stents, this technology will become more mature and thus has great potential.

Figure 4 Cannulation process of the two endoscope outer sheaths. A: The endoscope outer sheaths were inserted through the guidance wire; B: Ultrasound(US) image of one sheath (white arrow indicates the track of the sheath; the tip of the sheath was hidden in the US shadow and could not be displayed); C: Position of the sheaths in the anteroposterior X-ray image; D: Position of the sheaths in the lateral X-ray image.

Figure 5 Percutaneous endoscopic lumbar discectomy for lumbar disc herniation at two levels. A: Partial hypertrophied facetectomy was performed using a 3.0-mm endoscopic lateral bur; B: Percutaneous endoscopic lumbar discectomy was performed for lumbar disc herniation at two levels at the same time; C: Direct visualization of the blue dye in the protruding intervertebral disc through the endoscope; D: The protruding intervertebral disc was removed to decompress the spinal nerve.

Figure 6 Straight leg elevations before and after percutaneous endoscopic lumbar discectomy. A: Straight leg elevation was 40 degrees before percutaneous endoscopic lumbar discectomy (PELD); B: Straight leg elevation increased to 90 degrees after PELD.

Figure 7 Lumbar spine magnetic resonance imaging before and after percutaneous endoscopic lumbar discectomy. A: Transverse section suggesting L3-4 disc herniation (white arrow, left margin type); B: Same section 1 day after percutaneous endoscopic lumbar discectomy (PELD) (black arrow indicates disappearance of the herniation); C: Transverse section suggesting L4-5 disc herniation (white arrow, left margin type); D: Same section 1 day after PELD (black arrow indicates disappearance of the herniation); E: Sagittal section suggesting L3-4 and L4-5 disc herniations (white arrows); F: Same section 1 d after PELD (black arrows indicate disappearance of the herniations).

主站蜘蛛池模板: 亚洲中文字幕23页在线| 国产又粗又爽视频| 啦啦啦网站在线观看a毛片| 波多野结衣二区| 四虎永久在线精品国产免费| 亚洲a级在线观看| 99精品免费欧美成人小视频| 青青操国产视频| 亚洲三级a| 亚洲有无码中文网| 2048国产精品原创综合在线| 色婷婷成人网| 亚洲人免费视频| 亚洲一区二区三区国产精华液| 久久特级毛片| 久久a级片| 亚洲欧美精品日韩欧美| 五月天久久综合| 青青青视频91在线 | 怡春院欧美一区二区三区免费| 97久久人人超碰国产精品 | 无码中字出轨中文人妻中文中| 国产精品毛片一区| 99热这里只有精品免费国产| 成人综合久久综合| 九九热精品在线视频| 99re视频在线| 亚洲精品国产自在现线最新| 中文字幕一区二区人妻电影| 野花国产精品入口| 欧美另类一区| 中文字幕永久在线看| 91精品国产91欠久久久久| 国产99精品久久| 日本久久久久久免费网络| 国产日韩精品欧美一区灰| 欧美a级完整在线观看| 一级毛片网| 高清色本在线www| 国产99在线| 亚洲区一区| 99在线免费播放| 久久精品人妻中文系列| 狠狠ⅴ日韩v欧美v天堂| AV在线天堂进入| 99这里只有精品在线| 国产真实乱子伦视频播放| AⅤ色综合久久天堂AV色综合| 国产免费看久久久| 尤物亚洲最大AV无码网站| 色综合a怡红院怡红院首页| 国产成人免费手机在线观看视频| 97免费在线观看视频| 一本一道波多野结衣一区二区 | 日韩免费毛片| 精品99在线观看| 日本一区高清| 日日噜噜夜夜狠狠视频| 5555国产在线观看| 亚欧美国产综合| 亚洲精品视频免费观看| 性欧美在线| 女人一级毛片| 尤物成AV人片在线观看| 亚洲自拍另类| 手机看片1024久久精品你懂的| 毛片网站在线播放| 老色鬼欧美精品| 欧美精品成人| 日韩欧美网址| 国产成人精品在线1区| 日本欧美一二三区色视频| 亚洲精品午夜天堂网页| 成人毛片免费在线观看| 国产在线观看人成激情视频| 日本免费一区视频| 亚洲欧美日韩另类| 国产人人射| 久久精品人妻中文系列| 国产福利免费视频| 亚洲国产精品一区二区高清无码久久| 这里只有精品在线播放|