摘 要: 研究一種基于ZigBee無線傳感技術的樓宇供暖監控系統,可以隨時隨地對樓宇內供暖狀況進行監控,實現全雙工模式監控,實時采集采暖用戶樓宇的溫度,結合住戶內部人員情況自動調節閥門,控制屋內溫度,實時對住戶供暖信息進行采集、抄表以及實現漏水檢測等功能。主要對ZigBee無線傳感節點的處理器模塊、數據采集模塊、通信模塊以及電源模塊等硬件系統進行設計,同時對無線傳感網絡各節點的處理器和模塊程序進行設計,以及對供暖監控中心的組態界面進行設計。實踐結果表明,該設計達到了預期目標。
關鍵詞: 無線傳感網絡; ZigBee; 樓宇供暖監控; MSP430
中圖分類號: TN915?34; TP27 文獻標識碼: A 文章編號: 1004?373X(2016)18?0061?04
Abstract: The building heating monitoring system based on ZigBee wireless sensor technology is studied in this paper, which can monitor the heating conditions in the premises whenever and wherever, achieve full duplex mode monitoring, perform real?time acquisition of building heating temperature, regulate valves automatically according to resident status, control indoor temperature, execute house heating information acquisition and meter reading in real time, and detect water leakage. The processor module, data acquisition module, communication module and power supply module of the ZigBee wireless sensor node are designed. The module program and processor of wireless sensor network node are designed. And also the heating monitoring center configuration interface is designed.
Keywords: wireless sensor network; ZigBee; building heating monitoring; MSP430
0 引 言
我國大部分地區在冬季主要采用24 h不間斷的集中供暖方式,計費方式基本按照用戶樓房的建筑面積計算。大部分地區采用的常規供暖方式沒有考慮用戶樓房內的實際溫度狀況,以及樓房內是否有人居住等,另一方面,采暖用戶不能隨時隨地地遠程監控自己住房內供暖情況。采暖用戶只能被動接受供熱,不能根據自身樓房的居住情況進行調節溫度和開關供暖閥門,采暖用戶實際需求熱量和繳納的取暖費不對等,造成了大量的能源浪費。隨著社會的不斷發展,人們越來越關注能源浪費現象,同時人們的經濟意識不斷增強,住房面積不斷增大,實施分戶供熱計費,實現遠程無線監控樓宇供暖狀況基本能夠解決現存問題,同時也是發展的潮流和趨勢[1?3]。……