摘 要:在工業現場鍋爐燃燒過程中,火焰檢測器是觀測鍋爐火焰燃燒狀態必不可少的,對鍋爐的安全運行是至關重要的。然而工業現場中有很多因素對火焰閃爍信號有很大的影響,白噪聲是非常重要的一個因素。為了準確判斷鍋爐的工作情況,我們對火焰閃爍頻率的特征、白噪聲和噪聲的小波分析進行了較為詳盡的描述,利用Daubechies小波的heursure閾值法對爐膛火焰信號中的白噪聲進行消噪,取得了較好的效果。
關鍵詞:小波;閾值;火焰閃爍頻率;消噪
中圖分類號:TP29 文獻標識碼:B
文章編號:1004-373X(2008)11-181-03
Noise Absorption to Flame Flicker Frequency Using Wavelet Threshold
XU Zhiru1,ZHANG Huaibo2
(1.College of Information Science and Electronic Technology,Jiamusi University,Jiamusi,154007,China;
2.Shanghai Bosch Rexroth HydraulicsAutomation Ltd.,Shanghai,200120,China)
Abstract:During the combustion of industrial burner,flame detector is essential to observe the state of combustion and vital to the safety of burner.But many factors have great influence to flame flicker signal at the industrial scene,white noise is very important.In order to judge the situation of boiler operation exactly,we describe at large about the feature of flame flicker frequency,white noise and wavelet of noise.The usage of Daubechies wavelet heursure threshold to absorb white noise in flame signal has a good result.
Keywords:wavelet;threshold;flame flicker frequency;noise absorption
1 引 言
火焰閃爍即光輻射強度的波動,反映了火焰的幾何脈動,熱輻射和壓力的擺動?;鹧骈W爍為燃料和供給空氣在初始燃燒區混合產生渦旋的結果。火焰閃爍的基本屬性——頻率被用來標示火焰的穩定性[1],因此閃爍頻率的可靠性對診斷和優化燃燒進程是非常重要的。國內外對火焰閃爍頻率的研究主要集中判定燃燒器是否工作正常[2],火焰檢測器的制造[3]和判斷火災是否發生[4]。同燃氣和燃油的火焰相比,燃煤火焰由于燃料性質(揮發分,水分,灰度和粒度),燃燒器類型和燃燒條件的不規則性,使火焰的振動特點變得更復雜。
工業爐膛內的火焰信號有較寬的頻譜[5],高頻端的信號較弱。然而在信號的整個頻譜范圍內都包含白噪聲,并且白噪聲在高頻范圍內占支配地位,只有作消噪處理,才能有效地表現原信號中的有用信息。